background image

5

1.13.

Moving parts are exposed when the cover is removed.

1.14.

Ensure all electrical connections are tight, to prevent overheating.

2. Caution!

2.1

.

Read all of these instructions and retain this guide for later use.

2.2.

Pass on this guide in the event of change of ownership of the installation site.

2.3.

Follow all warnings, cautions and instructions contained in this guide.

2.4.

Follow all warnings, cautions and instructions contained on or inside the Mira
Extreme.

2.5

.

The electrical installation must comply with the “Requirements for Electrical
Installations”

 

commonly referred to as the IEE Wiring Regulations, or any

particular regulations and practices specified by the local electricity supply
company, in force at the time of installation. The installation should be carried
out by an electrician or contractor who is registered or is a member of an
association such as:

2.5.1.

National Inspection Council for Electrical Installation and Contracting
(NICEIC), throughout the UK.

2.5.2.

The Electrical Contractors Association (ECA), England and Wales.

2.5.3.

The Electrical Contractors Association of Scotland (ECAS).

2.6.

The plumbing installation must comply with Water Supply Regulations/Bye-
laws (Scotland), Building Regulations or any particular regulations and
practices, specified by the local water company or water undertakers. The
installation should be carried out by a plumber or contractor who is registered,
or is a member of, an association such as:

2.6.1.

Institute of Plumbing (IOP), throughout the UK.

2.6.2.

National Association of Plumbing, Heating and Mechanical Services
Contractors (NAPH & MSC), England and Wales.

2.6.3.

Scottish and Northern Ireland Plumbing Employers’ Federation
(SNIPEF), Scotland and Northern Ireland.

2.7.

Anyone who may have difficulty understanding or operating the controls of any
shower should be attended whilst showering. Particular consideration should
be given to the young, the elderly, the infirm, or anyone inexperienced in the
correct operation of the controls.

2.8.

When the Mira Extreme has reached the end of its serviceable life, it should
be disposed of in a safe manner, in accordance with current local authority
recycling, or waste disposal policy.

Содержание Extreme Thermostatic

Страница 1: ...Therm ostatic THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER POWERSHOWER THERMOSTATIC UserGuide Installation TH ER M O STATIC...

Страница 2: ...13 7 Installation Before You Start 14 ConfiguringInletSupplies 15 ShowerInstallation 17 8 Commissioning GeneralCommissioning 22 Adjustable Maximum Temperature Setting 23 Temperature Override Button D...

Страница 3: ...n be disabled if required The product is fitted with a 15 mm dual entry push fit inlet manifold which allows pipe connections to the top bottom or rear of the power shower The inlet manifold also cont...

Страница 4: ...DO NOT operate the Mira Extreme if water leaks from the unit maintenance will be required before the Mira Extreme can be safely used 1 7 DO NOT allow the Mira Extreme to be run dry 1 8 DO NOT fit any...

Страница 5: ...5 2 The Electrical Contractors Association ECA England and Wales 2 5 3 The Electrical Contractors Association of Scotland ECAS 2 6 The plumbing installation must comply with Water Supply Regulations B...

Страница 6: ...and to confirm that the parts are included 1 MiraExtreme 1 x Mira Extreme Thermostatic Power Shower 9 1 x Push Fit Release Tool 3 x Rubber Wall Plugs 3 x Fixing Screws 3 x Rubber Feet 4 x Case Inserts...

Страница 7: ...7 Dimensions Section 4 All dimensions are nominal and in millimetres 310 95 117 80 66 28 20 210...

Страница 8: ...n 1 C with a 10 C change in the hot or cold water supply 1 4 2 The sensor effects a shut down to seepage in approximately 2 seconds if the cold supply fails 1 4 3 Shut down to seepage is achieved even...

Страница 9: ...to will also affect the perceived noise level solid walls will provide a quieter operation 2 Plumbing 2 1 Inlet 15 mm Push fit inlet manifold 2 2 Outlet 1 2 BSP to BS2779 3 Electrical 3 1 Appliance po...

Страница 10: ...ded on the back of the case allow air to circulate and water to drain from behind the appliance 1 8 WhenfittingtheMiraExtremewithwallentryinletsupplies itisrecommended that the supply pipework is seal...

Страница 11: ...the inlet pipework in an easily accessible position These valves will allow the water supply to be turned off quickly to the Mira Extreme for maintenance purposes 3 7 When using surface mounted inlet...

Страница 12: ...red head of water x mm Required head of water x mm 15 mm Elbow No of Elbows x 55 No of Elbows x 55 3 11 Long pipe runs and excessive use of 90 elbows will significantly reduce the head available to su...

Страница 13: ...s not suitable for the Mira Extreme Incorrect supply connections Cistern Other Hot Draw Offs Incorrect Installation Correct Installation 4 InstallationDiagrams To prevent operational difficulties the...

Страница 14: ...leopening TheMiraExtremecansupporttop bottomorwallentryconfigurationsforboththewater and power supplies Choose the appropriate configuration for your installation Refer to Configuring Inlet Supplies f...

Страница 15: ...the top bottom or back of the case For top and bottom entries a thinned section of the case covering the top or the bottom cable channel must be removed before the cable can be fitted Supply Pipework...

Страница 16: ...peratureknob 2 2 Unscrewthethreecoverretaining screws sufficiently to remove the cover Note The cover retaining screws are captiveandneednotberemoved 2 3 Lowerthecovergently takingcare not to apply an...

Страница 17: ...allow for the fitting and removal of the cover Ensure that when the hose retaining ring is placed on the lowest position on the slide bar there is a minimum distance of 25 mm between the handset and t...

Страница 18: ...ooden blocks however thesemethodsoffixingarebeyond the scope of this guide Warning Ensure the marked fixing points are not inline with buried cables and pipes before drilling 3 7 Drill 9 5 mm holes an...

Страница 19: ...ifold due to the water supply pressure 3 11 Ensure that the end of the supply pipework is cut squarely and free fromburrswhichcandamagethe inlet manifold seals Chamfer the end of the pipe to assist in...

Страница 20: ...ed in the channel in the back of the case 3 15 Connectthelive neutralandearth conductorsoftheelectricalsupply cable to the terminal block The supply cable earth connector should be sleeved 3 16 To ref...

Страница 21: ...the Mira Extreme The power shower will now require commissioning Refer to Commissioning General Commissioning and Commissioning Adjustable Maximum Temperature Setting 3 20 To install the shower fittin...

Страница 22: ...of the appliance Ensurethehosewasher is fitted 1 3 Turnthewatersuppliesfullyonat the isolating valves Check that waterisnotleakingfromthebottom of the case 1 4 Switch on the electrical supply to the...

Страница 23: ...se temperatures Note An adequate supply of hot water at least 12 C above the required temperature must be available for correct operation of the shower control Warning Resetting the temperature of the...

Страница 24: ...Cooler Turn spindle clockwise 2 6 Press the Stop button to stop the waterflow 2 7 Refitthetemperaturehubwiththe piponthetemperaturehubaligned to the slot on the thermostatic cartridge Securewiththere...

Страница 25: ...ng isrecommendedfortheyoung theelderly theinfirm oranyoneinexperienced in the correct operation of the controls Follow the instructions below to disable the temperature override button 3 1 Turn the te...

Страница 26: ...utton to start low flow of water 1 1 Pushthelowerflowcontrolbutton to start the flow of water 1 2 Pressthecorrectflowcontrolknob toobtainthedesiredflowofwater 1 3 Turnthetemperaturecontrolknob inthedi...

Страница 27: ...Adjustable MaximumTemperatureSetting Maximum shower ingtemperaturetoo hot Maximumtemperature incorrectly set Reset maximum temperature Re ferto Commissioning Adjustable MaximumTemperatureSetting Clean...

Страница 28: ...ted in correctly Appliance sited above coldwaterstoragecis tern Plumbing system fault airlock Open valves Contact your installer Contact your installer The appliance is not suitable for negative head...

Страница 29: ...cold tap Maximum shower temperaturetoohot Shower runs cold after 5 10 minutes Insufficiently sized pipework for both sys tems to be used to gether Insufficient storage of hot water in cylinder Showert...

Страница 30: ...ult airlock Blocked spray plate Open valves Clean filters Refer to Maintenance Inlet Manifold Check Valve The appliance is not suitable for negative head installations Refer to Installation Requiremen...

Страница 31: ...shing up detergent or soap solution and then wiped dry using a soft cloth 3 FrontCover RemovalandInstallation Warning Before proceeding turn off the electrical and water supplies The electricity suppl...

Страница 32: ...spectthe O seals and renew if required Before refitting the inlet filter cap lightly grease O seals with a silicone basedlubricant 4 4 Refitcomponentsinreverseorder 4 5 Restore the water supplies and...

Страница 33: ...ropriate circuit fuse removed Mains electrical connections are exposed when the cover is removed 5 1 Remove the front cover as detailed in Front Cover Removal and Installation 5 2 Disconnect the elect...

Страница 34: ...et port of the manifold 5 9 Inspect inlet manifold valve interface seals and renew if required Note When refitting the inlet manifold lightlygreasesealswith a silicone based lubricant Inlet Manifold M...

Страница 35: ...turn off the electrical and water supplies The electricity supply must be turned off at the mains and if applicable the appropriate circuit fuse removed Mains electrical connections are exposed when...

Страница 36: ...ayout and connections to the motor pump assembly 7 4 Release the bottom securing clip on the transfer tube and lift the motor pump assembly and the mounting block clear of the case Note Liftupthefront...

Страница 37: ...thewiringconnections to the solenoid coil 8 5 Unscrew the screw securing the solenoidvalveclampbracketwith aT10Torxscrewdriverandremove the bracket 8 6 Disconnectthewiringconnections to the motor Note...

Страница 38: ...plies The electricity supply must be turned off at the mains and if applicable the appropriate circuit fuse removed Mains electrical connections are exposed when the cover is removed 9 1 Remove the fr...

Страница 39: ...tions are exposed when the cover is removed Caution Disconnectwiringbypullingonlyonthebodyofthespadeconnectorandnot the wire itself 10 1 Follow instructions 9 1 to 9 5 in the Maintenance section to re...

Страница 40: ...mponents identified C 453 14 Filter Cap Assembly 453 15 Seal Pack components identified D 453 17 Extreme Temperature Knob Assembly 453 23 Mixer Valve Body components identified E 453 24 Inserts Rubber...

Страница 41: ...41 147 67 G 453 01 453 14 F A E A A 453 09 453 04 453 17 453 27 B E F B F F H A C D C D G F F E C G B C D F D 453 13 H H 2 SparePartsDiagram...

Страница 42: ...Notes...

Страница 43: ...Notes...

Страница 44: ...ineer to visit If later the performance of your shower declines consult this manual toseewhethersimplehomemaintenanceisrequired PleasecallourCustomerServicestotalkthedifficultythrough request service...

Отзывы: