Mira Essentials 7.5 Скачать руководство пользователя страница 32

32

P3498/1 (J89 J, K, L)

© Caradon Mira Limited,March 2000

Essentials  Showers

Caradon Mira Ltd
Cromwell Road,
Cheltenham GL52 5EP.

BS EN ISO 9001 : 1994

Reg. No.  FM 14648

The company reserves the right to alter product
specifications without notice.

Failing this, contact your installer to ensure that the product has
been installed and commissioned in full accord with our detailed
installation instructions. Our Customer Services is available, on
the number shown below, to advise you or your installer.

If this does not resolve the difficulty, contact our Customer
Services who will give every assistance and, if appropriate,
arrange for our local Service Engineer or Agent to call on a
mutually agreeable date.

If, through circumstances beyond our control, we are unable to
provide this cover we will, with prior agreement, authorise a
competent local installer to attend.

Within the Guarantee period there will be no charge for the parts
or labour insofar as a fault with our product is concerned.
However, it is important to appreciate that our Guarantee
extends to our product only and that it does not cover difficulties
arising    from    incorrect    installation   or   misuse.

During a Service visit a responsible person – familiar with the
purpose of the visit – should be present. Should our Service
Engineer or Agent be unable to gain access at the pre-arranged
time a callout charge may be made.

Payment for Service visits, if applicable, should be made
directly to the Service Engineer or Agent, using either Visa,
Access or a cheque supported by a banker’s card.

To contact us:-
For England, Wales and Scotland

Telephone 01242 262888
and ask for Caradon Plumbing Solutions Customer
Services

 For advice on product maintenance

 To order spare parts

 To arrange a service visit

 For product advice and problem solving

 To order Instruction Guides

 For your feedback on our products or services

By  Fax:

(01242) 282595 - 24 Hours

By  Post:

Caradon Plumbing Solutions, Cromwell Road
Cheltenham, Gloucestershire, GL52 5EP.

For Northern Ireland

By Phone: 028 9040 1909 – Monday to Friday 9am–5pm
By Fax:

028 9040 1235 – 24 Hours

By  Post:

Wm. H. Leech & Son Ltd., Unit 3,
34, Montgomery Road, Belfast, BT6 9HL.

For Eire

By Phone: Dublin 01 4591344 – Monday to Friday 9am–5pm
By  Fax:

Dublin 01 4592329 – 24 Hours

By  Post:

Modern Plant Ltd, Otter House, Naas Road,
Clondalkin, Dublin 22, Eire.

Guarantee

Caradon Plumbing Solutions guarantee this product
against any defect of materials or workmanship for one
year from the date of purchase, provided that the product
has been installed correctly and used and maintained in
accordance with the instructions supplied.

Any part found to be defective during the guarantee period
will be replaced or repaired – at our option – without charge,
provided that the product has been properly used and
maintained.

The product should not be taken apart, modified or
repaired except by a person authorised by Caradon Plumbing
Solutions.

Your statutory rights are in no way affected by this
guarantee.

After Sales Service – how we can help
you

Caradon Plumbing Solutions have a team of expert staff
ready to provide assistance, should you experience any
difficulty with your Essentials shower.

The Caradon Plumbing Solutions Customer Services is
available to give you advice on any problem encountered.
Should the problem be unable to be resolved by advice,
we will offer either a replacement part to be sent to you,
or for one of our Service Engineers or Agents to call.

Spare Parts

At Caradon Plumbing Solutions we keep a stock of all
functional parts of our products for up to ten years from
the date of final manufacture of the product.

If during that period, our stock of a particular part is
exhausted we will, as an alternative, provide an equivalent
new product or part at a price equating to the cost of repair
to the old, bearing in mind the age of the product.

Caradon Plumbing Solutions will normally despatch spare
parts within two working days and by 1st class post. In
the interests of customer safety, spares that require
exposure to areas of mains voltage can only be sent to
a competent person.

Payment for such parts – if applicable – can be made by
Visa or Access over the phone at the time of ordering.
Should payment by cheque be preferred a pro forma
invoice will be sent.

Customer Care Policy

If within a short time of installation the product does not
function correctly, first check with the Instruction Guide to
see if the difficulty can be overcome by simple home
maintenance.

www.essentials-showers.com

Section

Customer Service

email:  [email protected]

Содержание Essentials 7.5

Страница 1: ...1 7 5 8 5 and 9 5 kW INSTRUCTION MANUAL ELECTRIC SHOWER THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER back ...

Страница 2: ...Contents Checklist 6 Dimensions 7 Wiring Diagram 8 Specifications 9 Installation Requirements 9 Installation 14 Commissioning 18 Operation 19 Maintenance 23 Fault Diagnosis 25 Spare Parts 30 Accessories 30 Guarantee Customer Care Policy and How to contact us Back cover ...

Страница 3: ...AC heater with an adjustable spray handset with three different spray actions start force and soothe Individual lights indicate POWER LOW PRESSURE and OVERHEAT Supplied complete with flexible hose adjustable clamp bracket assembly slide bar and supports and hose retaining ring Available in white chrome finish Essentials 8 5 A 8 5 kW 240 V AC 7 8 kW 230 V AC heater with an adjustable spray handset ...

Страница 4: ... exposed to freezing conditions 7 DO NOT fit any form of outlet flow control as the outlet acts as a vent for the tank body Only Caradon Plumbing Solutions recommended outlet fittings should be used 8 There are no user serviceable components beneath the cover of the appliance Only a competent tradesperson should remove the cover 9 If any of the following conditions occur isolate the electricity an...

Страница 5: ...ur electricity supply company to ensure that the electricity supply is adequate for the purpose 6 The plumbing installation must comply with the requirements of UK Water Regulations Bye laws Scotland Building Regulations or any particular regulations and practices specified by the local water company or water undertakers The installation should be carried out by a plumber or contractor who is regi...

Страница 6: ...elf with the part names and to confirm that the parts are included 2 Documentation 1 x Instruction Manual 1 x Guarantee Card Section Pack Contents Checklist 1 Essentials 7 5 8 5 or 9 5 kW 1 x Essentials 7 5 8 5 or 9 5 3 x Fixing Screws 3 x Wall Plugs ...

Страница 7: ...7 Section Dimensions 200 mm 83 mm 345 mm ...

Страница 8: ...ACITY 3 mm CONTACT SEPARATION GREEN YELLOW BROWN 220 240V ACONLY HEATER TANK BLUE L E GREEN 61A BLUE 58 BLUE 59A GREEN 60 C C1 A A2 A1 B B1 BROWN 59A SWITCH ASSEMBLY NEON ASSEMBLY RED 57 THERMAL SWITCH ORANGE 56 BROWN 53 RED 54 N RED 59A BROWN 57 BROWN 55 PURPLE 59A ...

Страница 9: ...tained inlet head of water of 8 metres the vertical distance from the base of the cold water storage cistern to the shower fitting handset To reduce pressure losses and fluctuations the cistern fed water supply must be independent from other supply draw offs and should avoid long horizontal pipe runs and use swept bends rather than 90 elbows The appliance may be installed with a shower pump to inc...

Страница 10: ...ver it is advisable to seal around the incoming mains fed supply to prevent water ingress into the wall 9 Do not install the appliance in a position where it may become frozen The shower unit must not be fitted where it may be exposed to freezing conditions The shower unit must not be used if suspected of being frozen 10 We recommend that a non restrictive free flowing isolating valve is fitted in...

Страница 11: ...inlet supply to the appliance cause a pressure build up which could exceed the maximum static inlet pressure for the appliance 16 Water flow can be obtained without the electrical power being connected This allows the plumbing connections to be tested prior to final connection of the electrical supply 17 Avoid layouts where the shower hose will be sharply kinked This may reduce the life of the hos...

Страница 12: ... provided by this unit use the shortest possible cable route from the consumer unit to the shower It is also necessary to satisfy the disconnection time and thermal constraints which mean that for any given combination of current demand voltage drop and cable size there is a maximum permissible length of circuit As a guide only the following maximum permissible lengths are given for 6 mm2 cable pr...

Страница 13: ...e live and neutral conductors as this will prevent them from entering the terminal block 8 DO NOT exert strain on the terminal block 9 DO NOT turn on the electrical supply until the plumbing has been completed Plumbing and Electrical Schematic Diagram ...

Страница 14: ...e wall It is recommended to use a soldered elbow 1 6 The inlet connector assembly is configured to suit a falling supply To change the configuration to suit a rising supply refer to Figure 2 remove the inlet strainer and compression nut refit the inlet connector and compression nut in the opposite ends 1 7 Removeas appropriatethethinnedcaseareas tosuit thesuppliesenteringthe product 1 8 Thoroughly...

Страница 15: ...ials shower must be fitted onto a finished flat and even wall surface small pillars moulded on to the back of the case allow air circulation Fixing Screw Inlet Connector Assembly Configuration For A Rising Supply Inlet Connector Assembly Configuration For A Falling Supply Inlet Connector Assembly Inlet Strainer Inlet Connector Assembly Inlet Strainer Make sure that the back inlet does not go into ...

Страница 16: ...s of the live and neutral conductors or strain the wires to the terminal block form a loop as shown 1 15 Fit an earth sleeve to the earth conductor Connect the conductors firmly into theterminalblock Makesurethatthebarecoresofeachconductoraresecurely trapped within each conductor clamp L Redwire N Black wire E Yellow Greensleevedwire 1 16 Re tighten the terminal block screws 1 17 If necessary fit ...

Страница 17: ...sitioned tofitontothespindlesallowing the cover to fit properly Fit and tighten the three cover retaining screws 1 19 Fit the shower fittings Refer to separate instructions Overheat Overheat Power Low pressure Low pressure Temp ratu e e r S t o p Low Med H i g h Spindle Positions when replacing Cover Figure 4 D Spindle ...

Страница 18: ...low will be reduced and the temperature will remain cool this shows that the flow regulator assembly is operating correctly Return the knob to full flow 7 Turn the left hand knob to the Med position The temperature of the water should rise slightly Allow a few seconds for the warm water to reach the handset this shows that the half power setting is operating correctly 8 High position The temperatu...

Страница 19: ...ll require the Temperature knob to be adjusted as necessary 5 The appliance requires a minimum pressure of 0 8 bar to operate At pressures above 0 8 bar the appliance will minimise the temperature fluctuations caused when other draw off points are used If the flow rate drops below an acceptable value the appliance will turn the heater elements off resulting in a cold shower The Low pressure neon o...

Страница 20: ...20 SelectShower TemperatureBy RotatingClockwiseAs Necessary EssentialsControls Figure 6 ...

Страница 21: ... setting with an incoming water supply at10 Candashoweringtemperatureat42 C thetemperatureriseis32 C Theflowrate is therefore 4 l min a These curves are for the specified outputs at 240V b Allapplianceheatingelementshaveamanufacturingtolerance Thusflow rates can be above or below those indicated c The left hand scale is temperature rise Temperature rise Showering temperature minus the incoming col...

Страница 22: ...owly to adjust temperature Allow 10 15 seconds for the adjusted temperature to reach the handset The control knob operates through approximately of a turn from cold to hot Clockwise rotation will give warmer water with less flow Anticlockwise rotation will give cooler water with more flow Note Should the product alternate Hot Cold Adjust the right hand control knob anti clockwise to reduce the tem...

Страница 23: ...ns 5 Refit the components in reverse order Maintenance Cleaning Many household cleaners contain abrasives and chemical substances and should not be used for cleaning plated or plastic fittings These finishes should be cleaned with a mild washing up detergent or soap solution and then wiped dry using a soft cloth General Read the section Important Safety Information first Providingtheshowerhasbeenc...

Страница 24: ...over and the relief valve assembly and will fall out when the cover is removed 2 Use suitable pliers to remove the relief valve assembly Do not remove the O seal 3 Moisten the rubber ball and insert it into the inner end of the relief valve assembly 4 Refit the components in reverse order Refer to the INSTALLATION section of this guide or the label inside the cover for the correct alignment of spi...

Страница 25: ...e clean Refer to Maintenance in the Shower Fittings Instruction Manual Incoming water supply stop valves or appliance isolating valve turned down or off Low pressure light illuminated Turn stop isolating valve fully to fully on position HoseorHandsetblocked Clearblockageorrenew Appliancefailsto produce hot water in anyswitchposition Electricalsupplyisolatedat doublepoleswitch the pullcord Switchon...

Страница 26: ...ppliance isolating valve turned fully on If fault still persists contact your installer Unable to select a cool enoughshower duringsummermonths Due to the rise in water mainssupplytemperature the power rating may be too high Turn the left hand knob to LOW settingandre adjust temperatureknobuntilsuitable temperatureisachieved Operationof temperatureknobhas little or no effect on watertemperature Re...

Страница 27: ...olved WARNING There are no user serviceable components beneath the cover of the appliance Only a competent tradesperson should remove the cover Key light illuminated A POWER indicator B LOW PRESSURE indicator C OVERHEAT indicator Malfunction A Cause Remedy C B No water or very low flow rate Handsetsprayplate assemblyblocked Remove and clean refer to Maintenance in the Instruction Manual for the sh...

Страница 28: ...erature Turn the right hand knob sufficientlyanticlockwise to increase the water flowandprevent operation of the thermal switch DONOTtamper with the thermal switch Appliancefailsto producehotwater in any switch position Electricalsupplyisolatedat doublepoleswitch the pullcord Switchon Fuse blown orMCB RCD tripped indicating an electrical fault e g heater tankelementfailure Correct the fault and re...

Страница 29: ...is blocked or the unit is frozen When the relief valveoperatesasmall rubber ball is ejected Reset the relief valve assembly refer to Maintenance Relief ValveResetting Renew the pilot valve Contactlocalwater authority undertaker Checkwatersupply staticpressure Note Staticpressure may fall below 0 5 bar whenotherappliances areoperatede g dishwasher washing machineetc Pilot valve faulty Supplypressur...

Страница 30: ... Assembly 7 5 kW 240 V AC 6 85 kW 230 V AC 43194 Heater Tank Assembly 8 5 kW 240 V AC 7 8 kW 230 V AC 43195 Heater Tank Assembly 9 5 kW 240 V AC 8 7 kW 230 V AC 43196 Inlet Connector Assembly 43197 ServiceTunnel 43199 Neon Assembly 87228 Microswitch C O 3 pin Accessories DCV H Outlet double check valve DCV H Anoutletdoublecheckvalve designedtopreventthebackfloworbacksiphonage ofpotentiallycontamin...

Страница 31: ...nnectors must be assembled back to back onto terminals of microswitches A minimum gap of 4 mm must be maintained between the connectors after assembly 431 96 419 82 419 86 431 76 431 75 417 46 872 28 431 93 431 94 431 95 147 50 431 92 419 88 431 97 431 87 431 86 431 99 ...

Страница 32: ... Phone Dublin 01 4591344 Monday to Friday 9am 5pm By Fax Dublin 01 4592329 24 Hours By Post Modern Plant Ltd Otter House Naas Road Clondalkin Dublin 22 Eire Guarantee Caradon Plumbing Solutions guarantee this product against any defect of materials or workmanship for one yearfromthedateofpurchase providedthattheproduct has been installed correctly and used and maintained in accordance with the ins...

Отзывы: