![Mira Essentials 7.5 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/mira/essentials-7-5/essentials-7-5_instruction-manual_1805068016.webp)
16
Installation of the Essentials Electric Shower - Electrical
Figure 3
1.11.
Install the mains-fed cold water supply pipe.
1.12.
Make the connection to the mains-fed cold water supply pipe.
1.13.
Bring the electrical supply cable into the case through one of the cable entry
points (refer to Figure 3).
1.14.
Strip back sufficient of the outer cable insulation to enable routing to terminal
block. Do not twist the individual cores of the live and neutral conductors or
strain the wires to the terminal block form a loop as shown.
1.15.
Fit an earth sleeve to the earth conductor. Connect the conductors firmly into
the terminal block
.
Make sure that the bare cores of each conductor are securely
trapped within each conductor clamp.
L
= Red wire
N = Black wire
E = Yellow/Green sleeved wire.
1.16.
Re-tighten the terminal block screws.
1.17.
If necessary, fit an earth bonding clamp to the copper supply pipe and ensure
bonding complies with relevant regulations in force at the time of installation.
Electrical Supply
Cable
Terminal Block
Form a loop in the
electrical supply
cable