![Mira Essentials 7.5 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/mira/essentials-7-5/essentials-7-5_instruction-manual_1805068021.webp)
21
Temperature rise versus flow rate for the Essentials range
Flow rate (litres per minute)
Temperature
rise
°C
8.5kW
7.5kW
12
11
3
2
6
7
10
9
8
5
4
10
15
20
25
30
35
40
45
50
55
Example:
For the Essentials 8.5 kW on full power setting with an incoming water supply
at 10°C and a showering temperature at 42°C, the temperature rise is 32°C. The flow rate
is therefore, 4 l/min.
(a)
These curves are for the specified outputs at 240V.
(b)
All appliance heating elements have a manufacturing tolerance. Thus flow
rates can be above or below those indicated.
(c)
The left-hand scale is temperature rise. (Temperature rise = Showering
temperature minus the incoming cold water temperature.)
9.5kW