![Mira Essentials 7.5 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/mira/essentials-7-5/essentials-7-5_instruction-manual_1805068026.webp)
26
Malfunction
Cause
Remedy
The temperature knob is
incorrectly fitted.
Contact your installer to correct.
Handset sprayplate blocked.
Remove and clean: Refer to
Maintenance
in the Instruction
Manual for the fittings
.
Other outlets being used
whilst showering, causing
water pressure to drop
below minimum required
to operate appliance.
Low pressure light
illuminated.
Ensure other outlets e.g. bath,
washing machine or dishwasher
are not in use whilst showering.
Water pressure below
minimum required for
appliance operation.
Low pressure light
illuminated.
Ensure incoming water supply
stopcock and or appliance
isolating valve turned fully on .
If fault still persists contact your
installer.
Unable to select a
cool enough shower
during summer months.
Due to the rise in water
mains supply temperature,
the power rating may be too
high.
Turn the left hand knob to LOW
setting and re-adjust
temperature knob until suitable
temperature is achieved.
Operation of
temperature knob has
little or no effect on
water temperature.
Remove Handset and clean
(Refer to
Maintenance
in the
Instruction Manual for the
shower fittings). If fault still
persists contact your installer.
Handset sprayplate blocked.
Water still flows when
electrical supply is
isolated.
Shower has not been turned
off at appliance control
knob.
The shower must be turned
off at the appliance. Water flow
isolation is manually operated
not electrical.