Specifications
1. Plumbing
1.1
The 15 mm inlet compression connector incorporates an inlet filter. The inlet
swivels to allow top, bottom or rear entry.
1.2
the outlet terminates with a 1/2" BSP male thread for connection to a mira
flexible shower hose.
2. electrical
this is a high power unit, it is essential to contact your electricity supply company
to make sure that the electricity supply is adequate for the purpose.
2.1
the terminal block will not accept cable larger than 16 mm
2
.
2.2
The motor is fitted with a self resetting thermal trip protection device, designed
to operate if the ambient temperatures become too high. the maximum
recommended ambient temperature for the elite St is 30°c.
2.3
the following power ratings for the heater tanks are available with their respective
voltages: mira elite St 9.8 kw @ 240 V / 45 Amps (9.0 kw @ 230 V / 40
Amps).
2.4
the motor will absorb approximately 100 watts maximum power under normal
working conditions.
3. standards and approvals
3.1
the mira elite St has been designed to comply with the requirements of the
British electrotechnical Approvals Board (BeAB) and the requirements of UK
water regulations/Bye-laws (Scotland).
3.2
this mira elite St complies with all relevant directives for ce marking.
Содержание Elite ST
Страница 21: ...21 Operation of the Mira Elite ST COLD Stop Start High Medium Low User Instructions...
Страница 28: ...28 Dimensions Power Low Flow Low High Temperatur e Start Stop Medium 340 mm 344 mm 659 mm 266 mm 95 mm...
Страница 34: ...34 Notes...
Страница 35: ...35 Notes...