A non restrictive (free flowing) isolating valve should be fitted into the supply
from the cold water cistern, for maintenance purposes.
1.5
The Elite ST must be fitted
oNto
the finished wall surface i.e. on top of the
tiles.
Do noT
block the air ventilation gaps around the sides of the unit, either
by tiling up to the sides of the unit or by using a sealant around the case.
important!
this elite St is designed to be ventilated. Failure to do this may
cause product failure.
note!
The Mira Elite ST is fitted with a pump motor, and some mechanical
noise can be expected in addition to the noise generated by the spray from
the handset. the type of wall surface will affect the perceived sound levels.
Stud partition and panel walls have a tendency to resonate, whilst solid walls
provide the quietest operation. the tone of the pump motor may change when
the temperature control knob is adjusted. This is quite normal.
1.6
Inlet: 15 mm inlet compression connector is designed to accept plumbing supplies
from the top, bottom or rear.
1.7
rear entry plumbing is accommodated without the need to recess the 15 mm
inlet compression connector, enabling the wall’s surface to be completed and
sealed to prevent water ingress, before final fitting.
1.8
Swivel the inlet connector assembly to suit (not directly back into the wall). Avoid
trapping the green earth bonding wire.
1.9
Use only the 15 mm inlet compression connector supplied with the elite St, do
not use any other types of fitting.
1.10
Outlet: 1/2" BSP male, to accept Mira flexible hose.
1.11
refrain from applying excessive force when making connections.
note!
excessive force on the pump housing can impair pumping performance.
make sure that the supply pipe is trimmed and bent such that the 15 mm inlet
connector sits (or can be lightly pressed) easily on the back of the clamp bracket
prior to connection with the pump housing.
1.12
To avoid damage to the case when soldered fittings are used, pre-solder the
pipework and fittings before connecting them to the 15 mm inlet compression
connector.
1.13
Supply pipework MUST be flushed to clear debris before connecting the
elite St.
Содержание Elite ST
Страница 21: ...21 Operation of the Mira Elite ST COLD Stop Start High Medium Low User Instructions...
Страница 28: ...28 Dimensions Power Low Flow Low High Temperatur e Start Stop Medium 340 mm 344 mm 659 mm 266 mm 95 mm...
Страница 34: ...34 Notes...
Страница 35: ...35 Notes...
Страница 36: ...36 1056830 W2 B Kohler Mira Limited July 2006 Customer Service UKAS...