Unable to
select a cool
enough
temperature.
due to a rise in the stored
water temperature, the
power rating may be too
high.
turn the toP knob to
medIUm setting and
re-adjust temperature
knob until suitable
temperature is achieved.
handset sprayplate
blocked.
remove and clean.
Shower
cycles from
hot to cold.
temperature knob or
heater setting too high.
turn the toP knob to
medIUm setting and
re-adjust temperature
knob until suitable
temperature is achieved.
Fault Diagnosis
symptom
Probable cause
Possible remedy
Elite ST fails
to operate.
electrical supply isolated
at double pole switch.
Switch on electrical
supply via pullcord or
wall mounted switch.
Incoming water supply
isolating valve turned
down or off.
turn isolating valve to
fully on position.
No water
or very low
flow rate.
h o s e o r h a n d s e t
sprayplate blocked.
remove and clean.
Fuse blown or mcB/rcd
tripped indicating possible
electrical fault.
renew the fuse or reset
the mcB/rcd. If fault
persists, contact your
installer.
The trouble shooting information below gives details on probable causes and remedies should difficulties
be encountered whilst the shower is in operation.
warning!
there are no user serviceable components beneath the cover of the appliance.
onlY a comPeTenT TraDesPerson shoulD remoVe The fronT coVer!
Power
light
low
flow
light
heater setting
low / medium
/ high
Any
oFF
oFF
Any
oFF
oFF
Any
oN
oN
Any
oN
oN
medium / high
oN
oFF
high
oN
oFF
medium / high
oN
oN
Содержание Elite ST
Страница 21: ...21 Operation of the Mira Elite ST COLD Stop Start High Medium Low User Instructions...
Страница 28: ...28 Dimensions Power Low Flow Low High Temperatur e Start Stop Medium 340 mm 344 mm 659 mm 266 mm 95 mm...
Страница 34: ...34 Notes...
Страница 35: ...35 Notes...
Страница 36: ...36 1056830 W2 B Kohler Mira Limited July 2006 Customer Service UKAS...