No water
and motor
tone
increases.
cistern has run out of
water.
turn off the elite St
immediately and resolve
cistern storage difficulty.
Internal pump unit faulty
or thermal trip has
operated.
wait for internal pump /
shower to cool down. If
still faulty contact your
installer.
remove handset and
clean.
handset sprayplate
blocked.
symptom
Probable cause
Possible remedy
Power
light
low
flow
light
heater setting
low / medium
/ high
medium / high
oN
oN
Any
oN
oN
Any
oN
oN
Low or no
flow.
Any
oN
oN
Filter or water supply
pipework restricted by
a blockage or partial
blockage.
Flush supply pipe.
Clean filter.
Any
oN
oFF
h o s e o r h a n d s e t
sprayplate blocked.
remove and clean.
Handset
dripping.
Any
oFF
oFF
Flow Valve faulty.
replace.
(continued . . .)
Any
oN
oN
Insufficient water supply
pressure / flow for
operation.
Gravity fed system,
minimum pressure 0.8
kPa (0.008 Bar / 80
mm).
Any
oN
oFF
Flow Valve faulty.
replace.
Any
oN
oFF
heater tank excessively
scaled.
replace. In hard water
areas consider the use
of a water softener.
all of The followinG remeDies musT onlY be PerformeD bY a
comPeTenT TraDesPerson!
Содержание Elite ST
Страница 21: ...21 Operation of the Mira Elite ST COLD Stop Start High Medium Low User Instructions...
Страница 28: ...28 Dimensions Power Low Flow Low High Temperatur e Start Stop Medium 340 mm 344 mm 659 mm 266 mm 95 mm...
Страница 34: ...34 Notes...
Страница 35: ...35 Notes...
Страница 36: ...36 1056830 W2 B Kohler Mira Limited July 2006 Customer Service UKAS...