13.0  WARRANTY 
 

MIRA,  Inc.  warrants  material  and  workmanship  of  the  CR  4000  Cryo  Console  for  a  period  of 
one year from the date of shipment. All accessories are warranted for a period of one year. Our 
obligation  under  this  warranty  is  limited  to  replacing  any  part  or  parts  which  shall,  upon 
examination at our factory, be determined to have been defective. The foregoing warranty shall 
apply  only  to  the  original  buyer,  and  is  and  shall  be  in  lieu  of  all  other  warranties,  whether 
expressed  or  implied,  and  of  all  other  obligations  or  liabilities  on  the  part  of  MIRA  Inc.,  to  be 
liable for any anticipated profits, consequential damages, loss of time or other losses incurred by 
the  buyer  with  the  purchase  or  operation  of  the  equipment  or  components  thereof.  Repair  to 
damaged parts will be made at a minimal charge. The buyer shall pay all shipping charges on the 
equipment being returned for warranty or charged repairs. Repaired equipment will be returned 
F.O.B.  our  plant.  For  prompter  service,  fill  out  and  return  the  warranty  card  supplied.. 

This 

warranty shall be void if a siphon cylinder is used or if any of the system components are 
tampered with.

 

 

14.0 CERTIFICATE OF CONFORMANCE

 

 

 
 

 

 
 
MIRA INC. 
414 Quaker Highway

 

UXBRIDGE MA 01569

 

Tel; 508-278-7877 
Fax: 508-278-2622 

 

 

 

Furnished  products  within  this  shipment  have  been  manufactured  in  accordance 
with  the  process  and  the  test  acceptance  criteria  requirements  of  specified 
drawings  and  specifications  listed  in  the  master  device  record  and  safety 
guidelines of MIRA INC. 

 

Calibration, when applicable has been done with the use of equipment traceable to 
the National Institute of Standards and Technology (USA)       

Содержание CR4000

Страница 1: ...First through innovation 0086 Mira Inc 414 Quaker Highway Uxbridge MA 01569 Tel 508 278 7877 800 847 6472 Fax 508 278 4555 p 1 OPHTHALMIC CRYOUNIT CR4000 OPERATIONAL INSTRUCTION MANUAL...

Страница 2: ...er Hose CR4160 6 3 7 Cryo Equipment Carrier Single Dual Cylinder capacity CR4150 7 3 8 CR4000 Instructional Video CR40x 8 3 9 Ophthalmic Probes 8 4 0 Initial Set Up Procedure 8 5 0 Foot Switch Operati...

Страница 3: ...t which can obscure the surgeon s view The MIRA CR4000 has a rapid freeze and defrost cycle available providing greater control of application time Temperature settings for both CO2 and N2O allow for...

Страница 4: ...or changed When a cylinder is heated above room temperature it may exceed maximum pressure 900psi red zone In this situation allow the cylinder to equilibrate to room temperature Approx 70 F before us...

Страница 5: ...o Carriers that come with factory installed sintered metal filters With a Micro fiber or sintered metal Filter assembly attached For use with basic CR4000 systems IMPORTANT Micro fiber or sintered met...

Страница 6: ...ures as described in section 6 0 Sintered metal Filter element and O Ring replacement procedure CR5350 Proceed as in items 1 2 and 3 above 4 Remove the filter element 5 Inspect the sealing ring and re...

Страница 7: ...r N2O CR4290 T Yoke assembly for E 4in Cylinder CO2 CR4390 T Yoke assembly with Micro filter for E 4in Cylinder CO2 3 7 Cryo Equipment Carrier Single Dual Cylinder capacity CR4150 The CR4150 is specia...

Страница 8: ...ues The handles present an unobstructed view of the probe shaft and remain comfortable to the hand during use TABLE II Probe Model Numbers Model No Description Tip Diameter Ice Ball Size CR4010 Curved...

Страница 9: ...er hose to the rear panel fitting labeled System Exhaust Connect the other end to an aspiration system or equivalent Note Use of the scavenger hose will result in quieter operation of the CR4000 Check...

Страница 10: ...he 5 C temperature setting for Carbon Dioxide CO2 6 3 4 Depress the foot pedal for 10 seconds and then release 6 3 5 Wait 60 seconds while the exhaust gas is escaping from the rear scavenger port IMPO...

Страница 11: ...for repair WARNING Do not alter the shape of the probe tip The shape of the probe tip is vital to its proper function Any change to the probe tip will void the manufacturer s warranty 8 2 Cleaning The...

Страница 12: ...s completely non electric there are no electrical shock hazards The micro fiber filter Sintered metal filter assemblies prevent foreign particles or oils from entering the CR4000 console and probes Re...

Страница 13: ...efore patient treatment Turn the gas cylinder OFF and depressurize the CR4000 system before changing the Micro filter Sintered metal filter or O ring When the probe is not in use the protective cap sh...

Страница 14: ...er Place all probes in plastic bags Enter a brief note that includes the following Return Goods Authorization RGA Your full address for return of shipment Please include specific department Descriptio...

Страница 15: ...ncurred by the buyer with the purchase or operation of the equipment or components thereof Repair to damaged parts will be made at a minimal charge The buyer shall pay all shipping charges on the equi...

Отзывы: