SPECIFICATIONS
Plumbing Supply
Supply Source
Mains pressure cold water only
Minimum Dynamic Pressure*
50 kPa (0.5 bar)
(100 kPa (1 bar) BEAB Care)
Maximum Dynamic Pressure
500 kPa (5.0 bar)
Maximum Static Pressure
1000 kPa (10 bar)
Minimum Static Pressure**
20 kPa (0.2 bar)
Maximum Inlet Temperature
30°C (20°C BEAB Care)
Minimum Inlet Temperature
2°C (5°C BEAB Care)
Inlet Connection
½" BSP male & 15 mm compression
fitting.
Outlet Connection
½" BSP male fitting
Electrical Supply
Nominal Rating at 230 V
8.3 kW
9.0 kW
Nominal Rating at 240 V
9.0 kW
9.8 kW
Supply Fuse/Circuit Breaker
9.0 kW
40 Amps
9.8 kW
45 Amps
Residual Current Device RCD
30 mA
Supply Cable
No larger than 16 mm²
Note: Refer to current IEE regulations and
BS 7671 to determine minimum cable size.
Isolation Switch
45 Amp Double pole, with 3 mm contact
separation.
Maximum Ambient Temperature
30°C
Minimum Ambient Temperature
2°C
*
Recommended dynamic pressure of 100 kPa (1.0 bar) for full flow performance.
**
Static pressure must never fall below 20 kPa (0.2 bar) when other draw offs are in use, e.g. flushing
toilet. This is the minimum pressure required to keep the flow valve closed.
Standards and Approvals
The Mira Advance ATL complies with the requirements of the BEAB Care Mark
Standard and the relevant directives for CE marking.
The BEAB Care mark is invalid if the product is not installed and used in accordance
with the manufacturer's specifications and instructions.
The Mira Advance ATL Flex Extra Wireless (J97P) is in compliance with the essential
requirements and other relevant provisions of the R&TTE directive 1999/5/EC. A
copy of the declaration of conformity may be obtained by contacting Kohler Mira Ltd
UK customer services department. See back cover for details.