Mira Advance ATL J97A Скачать руководство пользователя страница 40

40

1170168-W2-D (1643) (J97A-H, J97P)

© Kohler Mira Limited, May 2013

Mira is a registered trade mark of 

Kohler Mira Limited.

The company reserves the right to alter 

product specifi cations without notice.

FM 14648

Guarantee

Your  product  has  the  benefit  of  our  manufacturer’s 

guarantee which starts from the date of purchase.

To activate this guarantee, please return your completed 

registration card, visit our website or free phone 0800 

0731248 within 30 days of purchase (UK only).

Within the guarantee period we will resolve defects in 

materials or workmanship, free of charge, by repairing or 

replacing parts or product as we may choose.

This guarantee is in addition to your statutory rights 

and is subject to the following conditions:

  ●  The guarantee applies solely to the original installation  

    under normal use and to the original purchaser only.

    The  product  must  be  installed  and  maintained  in 

    accordance with the instructions given in this user 

    guide.

  ●  Servicing  must  only  be  undertaken  by  us  or  our   

    appointed  representative. 

Note!

  if  a  service  visit   

    is  required  the  product  must  be  fully  installed  and  

    connected to services.

  ●  Repair under this guarantee does not extend the original

    expiry  date. The  guarantee  on  any  replacement   

    parts or product ends at the original expiry date.

  ●  For shower fi ttings or consumable items we reserve

    the right to supply replacement parts only.

The guarantee does not cover:

  ●  Call  out  charges  for  non  product  faults  (such  as 

damage or performance issues arising from incorrect 

installation,  improper use, inappropriate cleaning, 

lack  of  maintenance,  build  up  of  limescale,  frost 

damage, corrosion, system debris or blocked fi lters) 

or where no fault has been found with the product.

  ●  Water or electrical supply, waste and isolation issues.

  ●  Compensation  for  loss  of  use  of  the  product  or 

consequential loss of any kind.

  ●  Damage or defects caused if the product is repaired 

or modifi ed by persons not authorised by us or our 

appointed representative.

  ●  Routine  maintenance  or  replacement  parts  to 

comply with the requirements of the TMV 2 or TMV 

3 healthcare schemes.

  ●  Accidental or wilful damage.

  ●  Products purchased ex-showroom display.

What to do if something goes wrong

If  your  product  does  not  work  correctly  refer  to  this 

manual for fault diagnosis and check that it is installed 

and commissioned in accordance with our instructions.

If this does not resolve the issue, contact us for help 

and advice.

Extended Guarantees

A selection of protection plans are available that 

enable you to cover repair bills (excludes Eire). Ring 

01922 471763 for more details.

01 531 9337

Mira Customer Services Dept, Cromwell 

Road, Cheltenham, Gloucestershire, GL52 

5EP

Helpdesk  Service

  -  Ring  our  Customer 

Services Team for product advice, to purchase 

spare parts or accessories or to set up service 

visit. You can contact us via phone or e-mail, 

details  below.  Please  provide  your  model 

name,  power  rating  (if  applicable)  and  date 
of purchase.

Mira Showers Website (www.mirashowers.

co.uk)

Visit  our  website  to  register  your  guarantee, 

download  user  guides,  diagnose  faults, 

purchase  our  full  range  of  accessories  and 
popular spares, or request a service visit.

Spares and Accessories

 - We hold the largest 

stocks of genuine Mira spares and accessories. 

Contact us for a price or visit our website to 

purchase items from our accessory range and 
popular spares

Service/Repairs -

 No one knows our products 

better  than  our  nationwide  team  of  Service 

Technicians. We can carry out service or repair 

work to your product both during and after the 

guarantee  period. Ask  about  our  fi xed  price 

service repairs.

To Contact Us: UK

CUSTOMER SERVICE

E-mail: Visit 

www.mirashowers.co.uk/

contactus

To Contact Us: Eire Only

0844 571 5000

Fax: 01 242 282595

E-mail: CustomerServiceEire@

mirashowers.com

Содержание Advance ATL J97A

Страница 1: ...is product is suitable for mains fed cold water only Installation Guide Mira Advance ATL ADJUSTABLE TEMPERATURE LIMIT THERMOSTATIC 9 0 and 9 8 kW For SPARES ADVICE or REPAIRS Please call us on 0844 57...

Страница 2: ...chematic Diagram Drain Pump 17 Instantmatch by Whale Digital Pump 18 Wireless Installation 19 Wireless Signal Schematic Diagram 19 Drain Pump Registration 20 Drain Pump Test 20 Registration or Test Fa...

Страница 3: ...ault Diagnosis 25 1 Installer Troubleshooting Guide 26 2 Diagnostic Procedure 27 BEAB Care In Service Tests 32 Maintenance 35 Spare Parts and Accessories 36 Wiring Diagram 38 Customer Service Back Cov...

Страница 4: ...of two years from the date of purchase shower fittings for one year Fornon domesticinstallations MiraShowersguaranteetheMiraAdvanceATLagainst anydefectinmaterialsorworkmanshipforaperiodofoneyearfromth...

Страница 5: ...st be turned off at the mains and the appropriate circuit fuse removed if applicable 4 Mains connections are exposed when the cover is removed 5 Refer to the wiring diagram before making any electrica...

Страница 6: ...on Installation Requirements CAUTION 1 Read all of these instructions and retain this guide for later use 2 The electrical installation must comply to BS 7671 commonly referred to as the IEE Wiring Re...

Страница 7: ...n Template 1 x Guarantee Registration Document 1 x Olive 1 x Compression Nut 1 x Mira Advance ATL Standard or Standard Extra Instantmatch by Whale Pump supplied separately Or Or 1 x Mira Advance ATL M...

Страница 8: ...ch 45 Amp Double pole with 3 mm contact separation Maximum Ambient Temperature 30 C Minimum Ambient Temperature 2 C Recommended dynamic pressure of 100 kPa 1 0 bar for full flow performance Static pre...

Страница 9: ...own condition If pipework and or electrical cables enter the shower from the rear through a hole in the wall provision must be made to prevent water ingress back into the wall structure Route cable an...

Страница 10: ...tallation always provide mechanical support when making plumbing connections Upon completion of the installation ensure connections and back case are not under any stress due to misaligned pipework or...

Страница 11: ...DO NOT exert strain on the terminal block Make sure that the electrical connections are tightly screwed down 2 5 DO NOT turn on the electrical supply until the plumbing has been completed 2 6 Unless o...

Страница 12: ...low Valve Solenoid Connector Lead Socket Thermal Switch Element Assembly Clip secures thermal switch Outlet Sensor Connector Lead Sockets for the Flow Valve Turbine and Inlet Sensor and the Tank Assem...

Страница 13: ...mation on position of wireless devices 3 Remove cover screw 5 Turn inlet connector to suit supply pipe Do not trap green wire 6 C o m p l e t e a n y soldering required away from appliance 8 D O N O T...

Страница 14: ...e product by using this template to mark and drill into the wall Drill appliance case separately Do not use alternative screws to secure the cover Do not seal any part of the appliance Use the correct...

Страница 15: ...block 20 Do not use alternative screws to secure cover This can cause internal damage to appliance Do not seal around any part of appliance 21 Install shower fittings Refer to separate Installation a...

Страница 16: ...accessory 1 1759 125 not included Hardwire cable included For use with the Whale Instant Match Pump Wireless Instant Match For use with the Whale Instant Match Pump Wireless Instant Match J97H 32 11 A...

Страница 17: ...al Outlet Double Checkvalve 45 Amp Double pole Isolating Switch Mains Fed Cold Water Supply Signal Cable Connector Optional Consumer Unit Isolating Valve Unswitched Spur Instant Match Transformer Inst...

Страница 18: ...IVER SIGNAL Jumper location Mira Advance Flex Extra Wireless J97P only TYPE Drain Pump Shower Type Driver Signal 755 171 LK1 Hardwired 755 199 LK1 Hardwired 755 299 LK2 Hardwired 755 349 LK2 Hardwired...

Страница 19: ...ll reduce the operational range of any radio controlled product dramatically Interference from other radio signals can also reduce the ability of the shower and drain pump to register or communicate T...

Страница 20: ...ng signal interference are temporarily switched off Drain Pump Test 1 Set shower temperature to FULL COLD 2 Shower is OFF NO water is flowing Power Electric to shower is OFF Power Electric to pump is...

Страница 21: ...er Check jumper position inside shower cover is set to WIRELESS Drain pump STARTS but shower is NOT RUNNING Solution Shutdownshoweranddrainpumpandreregisterusingtheinstructions below 1 Power to shower...

Страница 22: ...there is no water after 5 seconds make sure that appliance has been primed 5 secs 2 Power to appliance check Start Stop for blue light 6 Push Start Stop to turn off appliance Pulsing light and beep in...

Страница 23: ...STOPPED flowing Power Electric is OFF 3 Turn Power Electric ON Within 30 seconds push and hold FLOW START STOP together OFF ON 2 Set Maximum Temperature Turn the dial to the desired position in the ta...

Страница 24: ...TOP to turn shower ON Check that maximum temperature is acceptable to the user COMMISSIONING FAILURES the commissioning cycle was stopped due to an error No flashing FLOW LIGHT solution Restart the co...

Страница 25: ...ve passed before starting the commissioning cycle Memory Model If the maximum temperature is adjusted after it has been stored in one or more of the memory buttons refer to section Operation Storing t...

Страница 26: ...ving the front cover and reconnect when maintenance is complete Mains connections are exposed when the cover is removed Refer to wiring diagram before making any electrical connections Make sure all e...

Страница 27: ...the shower off at the Start Stop Button observe phased shutdown DO NOT isolate the power at the pullcord isolator switch until the water flow stops 5 Turn off the power at the pullcord isolator switc...

Страница 28: ...Check Inlet Temperature not too high 0 An unidentified error has occurred 1 Replace Control PCB Cover 1 Incoming flow too low for appliance to operate safely 1 Check all plumbing isolator valves to th...

Страница 29: ...heck relay contacts Debris on contacts or welded closed 2 Check Ribbon Cable Connection 3 Replace Relay Board 4 Replace Control PCB Cover 5 Replace Thermal Switch 9 10 Internal Electrical Supply probl...

Страница 30: ...Error lights when unit is re started This error occurs when the shower has been incorrectly shutdown and the unit senses over temperature refer to ERROR 17 Advise the user on correct start stop proced...

Страница 31: ...is position 1 a Turn shower off and isolate electric power b Choose channel number 2 or 3 with the temperature control c Repeat steps 2 4 of the Drain Pump Registration instructions found in this gui...

Страница 32: ...y major repair If there is no significant change in the outlet water temperature greater than 1 C between the two inspections the in service test frequency may be reduced but must not exceed 12 months...

Страница 33: ...er flowing from the showerhead and measure the temperature of the water flowing from the funnel The temperature must be no more than 2 C above the maximum temperature setting Record the temperature on...

Страница 34: ...g details of all measurement equipment used This form is available to download at www mirashowers co uk Date Not Operating Normal Operation Restricted Supply Date Signature Terminal Block Voltage V In...

Страница 35: ...n cable from cover 3 Hold a spanner or other suitable grips across flats of the metal connector Unscrew filter using another spanner as shown Clean or replace filter as necessary Refit filter making s...

Страница 36: ...149 Flow Valve Assembly components identified C 1643 251 Cover and PCB Assembly Standard 1643 252 Cover and PCB Assembly Flex 1643 255 Cover and PCB Assembly Memory 1643 262 Cover and PCB Assembly Fle...

Страница 37: ...37 B 1829 062 1643 100 1643 101 1643 102 1643 103 1643 104 1643 105 1643 144 1643 105 1643 144 1643 251 1643 252 1643 255 1643 262 1643 112 B B B B 1643 114 C A C 416 38 A C 1829 063...

Страница 38: ...eparation L E Control Board CN8 Green Y Terminal Block Outlet Temperature Sensor One Shot Thermal Switch Blue Heater Tank Plumbing Connectors Outlet Inlet Pump Driver Board Fitted to Standard Extra an...

Страница 39: ...39 NOTES...

Страница 40: ...of the product or consequential loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine maintenance or...

Отзывы: