For drain pump only: Advance 'Extra' models
18
Drain Pump not communicating with Shower.
1.
Check power to Drain Pump.
2.
Check connection between Drain Pump
and Shower. If wireless, reregister the
signal and retest using the procedure in
this guide, see
'Drain Pump Registration'
.
3.
Wireless Channels.
It may be necessary to alter the shower's
wireless frequency to avoid radio
interference which can prevent the Drain
Pump from operating correctly.
There are 3 channels which can be
selected individually using 1-3 on the
temperature control.
Default frequency is position 1
a. Turn shower off and isolate electric/
power.
b. Choose channel number 2 or 3 with the
temperature control.
c. Repeat steps 2-4 of the Drain Pump
Registration instructions found in this
guide.
If more than one shower and pump
combination are operating in close
proximity to each other, make sure that
each shower is set to a different channel.
4.
Contact Customer Service.
Unattended Operation
The appliance has a built in ‘Shower Stop’ timer to protect from accidental unattended operation. This
feature automatically switches the shower off after 40 minutes of continuous use. Normal operation is
restored by re-selecting the
Start/Stop