1.2.4
CONTROLLER UNIT M3086EPA3/SE
The controller unit contains all the electronics necessary to calculate opacity corrections (window
compensation and stack exit correction {also known as stack taper ratio}) and averaged opacity values. The
controller performs alarm limits and operation checks, memory functions and helpful special operations as
well. The controller also provides a series of terminal connections to monitor system status via a DCS or
process control panel.
The controller is housed in a standard 19-inch rack mountable frame. Power to the controller unit is supplied
by an standard power plug, provided with the unit. The controller also has an incorporated serial link for
communications with the transmitter. Serial cable lengths should be kept below 600 m lengths. If this is not
possible, the optional fibre optic modem can operate at a maximum of 3000-meter distances. Local MIP
dealer must install the optional fibre optic modem on request.
1.3
SYSTEM INTERCONNECTIONS
For the electrical and optical connections between different components, see the drawings section ( number
6 ) of this manual.
1.4
MONITOR SPECIFICATIONS
The following specifications of the LM 3086 EPA3/SE monitor describe its technical features and performance
specifications. It should be understood that the installation environment will ultimately affect the
performance of the complete instrument.