background image

31

 

 

 

 

Manufacturer’s declaration-electromagnetic immunity

 

Test 

specifications

 for ENCLOSURE PORT IMMUNITY to RF wireless communications 

equipment

 

The N507 

is intended for use in the electromagnetic environment (for home healthcare) specified 

below.

 

The customer or the user of the N507 should assure that it is used in such an environment.

 

Test 

frequency

 

(MHz)

 

Band

a) 

(MHz)

 

Service

a)

 

Modulation

b)

 

Maximum 

power

 

(W)

 

Distance 

(m)

 

IMMUNITY 

TEST LEVEL

 

(V/m)

 

Compliance 

LEVEL

 

(V/m)

 

(for home 

healthcare)

 

385

 

380

 

–390

 

TETRA 400

 

Pulse 

modulation

b)

 

18 Hz

 

1,8

 

0,3

 

27

 

27

 

450

 

430 –

 

470

 

GMRS 460,

 

FRS 460

 

FM

c)

 

±5 kHz 

deviation

 

1  kHz sine

 

2

 

0,3

 

28

 

28

 

710

 

704 –

 

787

 

LTE Band 13,

 

17

 

Pulse 

modulation

b)

 

217 Hz

 

0,2

 

0,3

 

9

 

9

 

745

 

780

 

810

 

800 –

 

960

 

GSM 800/900, 

TETRA 800,

 

iDEN 820,

 

CDMA 850,

 

LTE Band 5

 

Pulse 

modulation

b) 

18 Hz

 

2

 

0,3

 

28

 

28

 

870

 

930

 

1 720

 

1 700 –

 

1 990

 

GSM 1800;

 

CDMA 1900;

 

GSM 1900; 

DECT;

 

LTE Band 1, 3,

 

4, 25; UMTS

 

Pulse 

modulation

b) 

217 Hz

 

2

 

0,3

 

28

 

28

 

1 845

 

1 970

 

Содержание MiCor A100

Страница 1: ...User Manual MiCor A100 Wearable ECGRecorder...

Страница 2: ...11 Setting the dateand time 11 Operating basics 12 Changing the display mode 12 Recording ECG data 13 Connecting the device toyour phone 14 Using the App 15 Viewing ECG data 15 Setting up the pro le 1...

Страница 3: ...adiation WEEE Waste Electrical and Electronic Equipment This product must not be disposed of as normal household waste in accordance with the EU directive for waste electrical and electronic equipment...

Страница 4: ...d behazardous This device is not a toy Do not allow children or pets to play with your device The device contains small components that can be chokinghazard Please do not place the device in your bag...

Страница 5: ...ot wear your device while chargingit Do not charge your device while it iswet Disperse any static electricity from your body before using the unit To avoid static electricity use a small metal device...

Страница 6: ...examination When using this unit in hospitals or other medical facilities use the unit under the supervision of yourdoctor The heart rate is calculated by using the auto correlation method to calcula...

Страница 7: ...with household waste Disposal of the packaging and your device should be done in accordance with local regulations Batteries are not to be disposed of in the municipal waste stream and require separat...

Страница 8: ...ld in memory meanwhile the device also display the real time heart rate The device can store 30 sets of ECG signal 30 seconds set of data then user can transfer ECG signal data from device to APP of t...

Страница 9: ...8 Getting to know your device 1 OLED screen 2 ECG sensor 3 MODEbutton 4 Charging connector 5 ECG sensor 6 Straps...

Страница 10: ...the instructions below to charge the battery 1 Remove the protection cover 2 Connect the magnet type USB charging cable to the device s charging connector 3 Connect the USB connector of the charger t...

Страница 11: ...ting on thedevice Putting on the device is like wearing a watch around your wrist Follow the instructions below to wrap the straps around your wrist and then secure it with the buckle The device comes...

Страница 12: ...trocardiogram save and managethe ECG data and more functions via your phone Setting the date and time To make sure that the date and time of your ECG recordings are correct check the settings before y...

Страница 13: ...y in time date displaymode ECG data amount Time 3 sec Date 2 sec Idle mode Press the MODE button twice to display the amount of ECG data stored in the device The device will automatically enter Idle m...

Страница 14: ...vibrating once the system enters ECG recording mode 4 Wait for 3 seconds and then the system will start recording ECG data Keep touching the ECG sensor for about 30 seconds and do not move until the r...

Страница 15: ...wnload and install MiCor A100 App on your phone 2 Make sure Bluetooth is activated and then launch the App 3 Complete the initial settings including the pro le and device settings Pro le Enter your na...

Страница 16: ...xamined and printed This App features useful functions such as changingof the scale and range of the ECG data to better observe speci c events which would be very helpful for doctor s reference Viewin...

Страница 17: ...y tappingAll Delete the selected records or all records by tappingDelete Tap Menu to display the menu screen allowing you to Select Sync now to start synchronization manually Select Pro le Settings to...

Страница 18: ...you can zoom in or out the waveform area by moving your ngertips apart or together on the screen Spread tozoom in Pinch to zoom out Tap on the Note led to take notes for the ECG data Tap Edit to displ...

Страница 19: ...18 Select Email to send the item byemail Select Print to print it out Select Delete to delete therecord...

Страница 20: ...gs 4 Connect the device Now you can choose the desired user from the User list after launching the App Connecting the otherdevices You can use the same App to manage the ECG data from different device...

Страница 21: ...by PhysiolGuard Biotechnology Inc U S Technical Support and Customer Service 21660 E Copley Drive Suite 170 Diamond Bar CA 91765 Email Tech support PhysiolGuard com Tel 1 909 394 5000 Product Speci c...

Страница 22: ...ted servicelife 1year Charging clip Type USB port Length 20cm Output Current 500mA Input Voltage 5V Output Interface Pogo Pin IP27 The IEC 60529 IP27 is a European system of test speci cation standard...

Страница 23: ...t case and or packaging Do not use the charger if the cord becomesdamaged Do not attempt to service the unit There are no serviceable parts inside Replace the unit if it is damaged or exposed to exces...

Страница 24: ...completely before use The screen surface can easily be scratched Avoid touching it with sharp objects Non adhesive generic screen protectors designed speci callyfor useon portabledevices with LCD pan...

Страница 25: ...dance with the instructions may cause harmful interferenceto radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cau...

Страница 26: ...that it is used in such an environment Emission test Compliance Electromagnetic environment guidance for home healthcare environment RF emissions CISPR 11 Group 1 The N507 uses RF energy only for its...

Страница 27: ...r input output lines 2kV for power supply lines Not applicable Mains power quality should be that of a typical home healthcare environment Surge IEC 61000 4 5 0 5kV 1kV line s to line s 0 5kV 1kV 2kV...

Страница 28: ...8 30 A m 50 Hz or 60 Hz 30 A m 50 Hz 60 Hz The N507 power frequency magnetic elds should be at levels characteristic of a typical location in a typical home healthcare environment NOTE UT is the a c...

Страница 29: ...ecommended separation distance d 1 2 P d 1 2 P 80 MHz to 800 MHz d 2 3 P 800 MHz to 2 5GHz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufac...

Страница 30: ...ength in the location in which the N507 is used exceeds the applicable RF compliance level above the N507 should be observed to verify normal operation If abnormal performance is observed additional m...

Страница 31: ...on distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 7 GHz d 2 3 P 0 01 N A 0 12 0 23 0 1 N A 0 38 0 73 1 N A 1 2 2 3 10 N A 3 8 7 3 100...

Страница 32: ...MHz Service a Modulation b Maximum power W Distance m IMMUNITY TEST LEVEL V m Compliance LEVEL V m for home healthcare 385 380 390 TETRA 400 Pulse modulation b 18 Hz 1 8 0 3 27 27 450 430 470 GMRS 460...

Страница 33: ...the distance between the transmitting antenna and the ME EQUIPMENT or ME SYSTEM may be reduced to 1 m The 1 m test distance is permitted by IEC 61000 4 3 a For some services only the uplink frequencie...

Страница 34: ...iesbetweenthedeviceand the documents Notes Not all models are available in all regions Depending upon the speci c model purchased the colour and look of your device and accessories may not exactly mat...

Страница 35: ...ion WEEE Waste Electrical and Electronic Equipment This product must not be disposed of as normal household waste in accordance with the EU directive for waste electrical and electronic equipment WEEE...

Отзывы: