Minuteman ED6200RM Скачать руководство пользователя страница 7

 

10

  On/Alarm Silencer switch is to turn the UPS On or silence the audible alarm in 

the Battery mode. 

  OFF switch is to turn the inverter Off and transfer the UPS to the Bypass mode. 

  Special functions key: Log in/out. 

  Down arrow: Go to next page. 

  Up arrow: Go to previous page or change the UPS setting. 

  Enter key: To save the changes to the UPS setting. 

 
 

2.5. 

Rear Panels 

 
2.5.1  UPS module (ED6200RM) rear panel 
 
 
 
 
 
 
 
 
 
 
 
 
 

A.  Dipswitch for the Parallel Redundant function. 

NOTE: 

The dipswitch must be in the Off position when the Parallel 

function is not being used. 
B. RS232 Port for monitoring and control. 
C. EPO (Emergency Power Off) Port 
D. Input Circuit Breaker. 
E. Connectors for Maintenance Bypass and Parallel Redundant function. 
F. Battery Connector for connecting a Battery Pack 
G. Cooling Fans 
H. Terminal block for Input & Output power connection. 
I. Option Slot 1 is for other option cards except the SNMP card and the 
Programmable Relay card. 
J. Option Slot 2 is for the SNMP card and the Programmable Relay card 
only. 

 

 

 

11

2.5.2  Isolation Transformer module (ED6000RMXFMR) rear panel 
 
 
 
 
 
 
 
 
 
 
 
 

A. Connectors for Maintenance Bypass and Parallel Redundant function. 
B. Terminal block for Transformer Output, UPS Output, and Utility Input. 
C. L6-30R for UPS input connection. 
D. Maintenance Bypass Switch. 

 
 
2.5.3  Battery Pack module (EDBP6000RM) rear panel 

NOTE:

 The Output receptacle box is an option. Not all Battery Packs have the 

Output receptacle box. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

A. Battery connector for connecting to the UPS module. 
B. DC circuit breaker. 
C. Battery connector for Daisy Chaining additional Battery Packs or for 
connecting an external charger. 
D. Cable for connecting the power to the output receptacles. 
E. Output receptacle box. 
 

 

Содержание ED6200RM

Страница 1: ...tems Inc 1455 LeMay Drive Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000315 R5 ED6200RM Parallel Redundant ON LINE SERIES User...

Страница 2: ...Installation of Castor Covers 14 3 5 Wiring the Input and Output Connections 18 3 6 RJ 45 cables for the Maintenance Bypass Operation 27 3 7 Operation and Setup Instructions 28 4 Communication Port EP...

Страница 3: ...enance of the UPS and batteries 1 1 12 CAUTION A disconnect switch must be provided by the user for the AC output circuit when the UPS s output is hardwired To reduce the risk of fire connect only to...

Страница 4: ...Parallel Redundant kit Contact your local distributor for more information concerning the Parallel Redundant operation 2 2 5 Maintenance Bypass Switch which reduces down time for maintenance 2 2 6 The...

Страница 5: ...Er03 PFC Boost soft start abnormal after 30 seconds 30 Er04 Inverter Failure 31 Er05 Battery Weak or Dead 32 Er06 Output Short Circuit 33 Er08 DC Bus high voltage level abnormal 34 Er09 DC Bus low vol...

Страница 6: ...59 CEr2 Bypass Voltage out of range 60 CEr3 Inverter Voltage out of range 61 CEr4 Load Percentage out of range 62 CEr5 Battery Voltage out of range 63 CEr6 UPS Output Voltage out of range Er7 Er19 Er2...

Страница 7: ...nnecting a Battery Pack G Cooling Fans H Terminal block for Input Output power connection I Option Slot 1 is for other option cards except the SNMP card and the Programmable Relay card J Option Slot 2...

Страница 8: ...cking material Since the manufacturer is not responsible for shipping damage incurred when the system is returned the original packing material is inexpensive insurance PLEASE SAVE THE PACKING MATERIA...

Страница 9: ...Pack and then connect UPS and the Battery Pack together S1 A3 S3 15 3 4 1 2 UPS Isolation Transformer and Battery Pack 3 4 2 Rack Installation 3 4 2 1 UPS Isolation Transformer and Battery Pack Step1...

Страница 10: ...ion Transformer and Battery Pack Step3 Install the Rails in the 4 post Rack S3 S3 17 Step4 Install the Battery Pack to the Rails Step5 Install the Rails in the 4 post Rack and then install the Isolati...

Страница 11: ...current protection device in accordance with the National Electric Code ANSI NFPA 70 Use 60 C copper wire and apply 22 1lb in of torque force when connecting to the terminal blocks Output Voltage and...

Страница 12: ...put of the Isolation Transformer A Qualified Electrical Contractor must perform the hardwiring The outputs must be connected to an over current protection device circuit breaker in accordance with the...

Страница 13: ...rom L22 to N11 L11 L1 N22 L2 G Earth Ground 240Vac 23 3 5 2 3 9 Configuration 5 Output Two separate circuits of 120VAC 3KVA loads 3KVA max load per circuit Total combined output load not to exceed 6KV...

Страница 14: ...e box to the TR OUTPUT terminal block 4 Has a Maintenance Bypass Switch see Section 3 6 for connecting the RJ 45 cables for the Maintenance Bypass operation 25 3 5 3 1 Application B 1 Utility Input 20...

Страница 15: ...L21 2 Connect a wire to the Output terminal N22 3 Connect a wire to the Output terminal G2 3 5 4 3 Application D 1 Utility Input 208 240VAC must be hardwired see Section 3 5 4 1 for wiring 2 UPS Outpu...

Страница 16: ...n Switch on the front panel for approximately 3 seconds then release The audible alarm will sound 2 beeps then the LCD display will change from drawing B to drawing C C 29 3 7 1 6 The UPS will perform...

Страница 17: ...release the audible alarm will sound 2 beeps The LCD display will change from drawing G to drawing H the UPS will be in self test mode The UPS will provide an output within approximately 1 minute and...

Страница 18: ...1 Once the UPS has successfully started up press the Special Function keypad to change the LCD display screen to drawing Q1 Q1 It shows the Buzzer is Enabled Q2 It shows the Buzzer is Disabled 3 7 4 2...

Страница 19: ...ws the bypass voltage is adjusted to the higher limit T It shows the Frequency Window is 3Hz 35 U It shows the Inverter Output Voltage setting V1 It shows the UPS is operated in the Normal mode V2 It...

Страница 20: ...can be changed to 184VAC 260VAC or 195VAC 260VAC 3 7 5 4 Drawing T means the bypass frequency window of the Inverter Output can be changed to 3Hz or 1Hz 3 7 5 5 Drawing U means the Inverter Output Vo...

Страница 21: ...PS system 3 7 8 1 1 Press the Off switch for approximately 5 seconds the LCD screen will display drawing B and the UPS will be in the Bypass mode 3 7 8 1 2 Remove the Maintenance Bypass Switch cover f...

Страница 22: ...UPS shuts down the fans will still be on In approximately 1 minute the fans will reduce speed To restart the UPS once the utility power returns Press the Off switch on the front panel for 2 beeps then...

Страница 23: ...43 7 Replacing the Batteries QUALIFIED SERVICE PERSONNEL ONLY Please read all of the WARNINGS and CAUTIONS before attempting to service the batteries WARNING This Uninterruptible Power Supply contains...

Страница 24: ...el of the UPS 7 1 4 Turn Off the utility power circuit breaker at the service panel 7 1 5 Disconnect all of the communications and network cables from the rear panel of the UPS 7 1 6 Turn Off the DC c...

Страница 25: ...reaker on the rear panel of the UPS if applicable 7 1 34 Press and hold the On Switch on the front panel for approximately 3 seconds then release if applicable 7 1 35 Turn On the equipment that is con...

Страница 26: ...tripped A tripped circuit breaker is the most common problem Call your dealer for assistance If you cannot reach your dealer or if they cannot resolve the problem call or fax MINUTEMAN Technical Suppo...

Страница 27: ...Except as provided herein Para Systems makes no warranties expressed or implied including warranties of merchantability and fitness for a particular purpose Some states do not permit limitation of imp...

Отзывы: