7 - Modbus register
40 / 66
4 DECEL
PWM on with deceleration control
5 STEADY
PWM on with non-zero speed control
6 STOPPING
PWM with deceleration until zero speed
Indicates the drive status.
7.3
Homing register
ID
NOME
DESCRIZIONE
NOTE
257
Homing type
Defines the homing type according to
the CanOpen CIA402 standard.
Equivalent to P152 parameter
RW 16-bit signed integer
Homing available:
1
15
33
35
258 - 259
Home Offset
Defines the offset value taken into
account during the homing.
Equivalent to P168
–
169 parameters
RW 32-bit unsigned integer
[User unit]
260
Homing switch
search speed
Defines the motor speed during the
research of the limit switch
Equivalent to P153 parameter
RW 16-bit unsigned integer
[rpm]
261
Homing index
search speed
Defines the motor speed during the
achievement of the index pulse
Equivalent to P154 parameter
RW 16-bit unsigned integer
[rpm]
262
Homing
acceleration
Defines the motor acceleration used to
reach the home settled velocity starting
from zero velocity
Equivalent to P155 parameter
RW 16-bit unsigned integer
[rpm/s]
263
Homing
deceleration
Defines the motor acceleration used to
reach the zero velocity starting from the
target velocity
Equivalent to P156 parameter
RW 16-bit unsigned integer
[rpm/s]