2 - Installation
11 / 66
2.6.1
CanOpen/Modbus RTU (55/---/C)
The wirings and LEDs in
Errore. L'origine riferimento non è stata trovata.
refer to the CanOpen/Modbus
RTU equipped version.
Figure 5
The pin function is the same for CN5 and CN6.
WARNING
: if more devices are connected
together, pin 3 (GND) need to be connected
ONLY
if the logic power supply is not common
(different GND).
Pin
CanOpen
Modbus RTU
1
Housing Shield
2
Not connected
3
CAN GND
GND
4
CAN H
485 B
5
CAN L
485 A
Details about Led status are explained on chapter 5.1
2.6.2
CanOPEN over EtherCAT (55/---/ETH)
The wirings and LEDs in Figure 10 refer to the CanOpen over EtherCAT equipped version.
Figure 6
The pin function is the same for CN5 and CN6.
CN5 connector --- input
CN6 connector --- output
Pin
CanOpen over EtherCAT
1
TX+
2
RX+
3
TX-
4
RX-
Details about Led status are explained on chapter 5.2