11 - Homing types
62 / 66
Index
Pulse
Home Switch
5
6
6
5
11.4
Type 5 and 6: homing on the negative Home Switch and Index Pulse (resolver zero)
The initial direction of movement depends on the state of the home switch. The reference (home) position
is on the index pulse (resolver zero) to the left (type 6) or right (type 5) of the switching point of the home
switch. If the starting position is such that a reversal of direction is required, the reversal takes place after
the state of the home switch changes
Figure 24