4 - Parameters
19 / 66
4
Parameters
4.1
Appl
4.1.1
User
ID
NAME
DESCRIPTION
NOTE
P001
Ref Source
Reference source
selection
1 Analog Input
1
Speed, Torque
2 Dig.Input
2
Speed, Torque, Position,
Homing
3 ModBus
3
Speed, Torque, Position,
Homing
4 Multispeed
1
Speed
5 CanOpen
3
Speed, Torque, Position,
Homing
6 CanOverECAT
6
Speed, Torque, Position,
Homing
7 Ethernet PowerLink
7
Speed, Torque, Position,
Homing
8 Ethernet/IP
8
Speed, Torque, Position,
Homing
9 Profinet IO
9
Speed, Torque, Position,
Homing
1
On mode 1, 4 and 5 enable, input shall be configured
3
On mode 3 and/or 5 the device shall be restarted. (only
version 55/---/C)
6
On mode 6 (CanOverEtherCAT) the device shall be
restarted (only version 55/---/ETH)
7
On mode 7 (Ethernet PowerLink) the device shall be
restarted (only version 55/---/EPL)
8
On mode 8 (Ethernet/IP) the device shall be restarted
(only version 55/---/EIP)
9
On mode 9 (Profinet IO) the device shall be restarted
(only version 55/---/EPN)
P016
Control Type
Motor control type
0 None
No control enable
1 Torque
Enable the torque control
2 Speed
Enable the speed control
3 Position
1
Enable the position control
1
Position control can be used only via Fieldbus
If
P001 = 5,6,7 or 8 this parameter hasn’t effect
P006
Speed Max
Max speed reference
0
4000 [rpm]
P007
Speed Min
Minimum speed
reference in Analog
mode
0
4000 [rpm]