78
D
F
−
21
Selection of output logic of BCD data
Initial value
=
00000
00000
=
Negative logic
00001
=
Positive logic
D
F
−
22
Selection of output logic of BCD polarity (POL)
Initial value
=
00000
00000
=
Negative logic
00001
=
Positive logic
D
F
−
23
Selection of output logic for BCD flag
(
ERROR
、
OVR
)
Initial value
=
00000
00000
=
Negative logic
00001
=
Positive logic
D
F
−
43
Setting CHECK value
Initial value
=
00003
Setting range
00000
〜
00015
Unit
:
0.1 mV/V
Approx. 1.5 mV/V of CHECK value with the setting
of “00015”.
D
F
−
50
Selection of the target of HOLD
Initial value
=
00003
00000
=
Ineffective for HOLD.
00001
=
HOLD only for display
00002
=
HOLD only for BCD output
00003
=
HOLD for both of display and BCD output
D
F
−
59
Selection of digital Tare weight cancellation
Initial value
=
00000
00000
=
Ineffective
00001
=
Effective
※
Selects whether digital Tare weight cancellation is to be effective or
ineffective.
D
F
−
60
Setting digital Tare weight cancellation value
Initial value
=
00000
Setting range
−
99990 to 99990
※
When digital Tare weight cancellation is to be “Effective” with F
−
59, digital
Tare cancellation for the set portion by this setting can be executed.
※
The following calculation should be made for digital Tare weight
cancellation against “Gross weight”.
(
Gross weight
)−(
Digital Tare weight cancellation value
)
=(
Display when digital Tare cancellation is effective.)
D
F
−
62
Setting the target of zero tracking
Initial value
=
00000
00000
=
Gross weight
00001
=
Net weight
D
F
−
70
Increment value (For reference)
※
The increment value set when the calibration is applied can be referred to.
※
In this function, change of setting can’t be made.
D
F
−
71
Maximum display value (For reference)
※
The maximum display value set when the calibration is applied can be
referred to.
※
In this function, change of setting can’t be made.