After the sum memory was written the Display-Weight shows the sum weight (= sum
value after takeover), Display-PW shows the number of elements in the sum memory
after take over, Display-Count shows the content of sum memory (only number of pieces,
no weights) after takeover. This state lasts for about 2 seconds.
If a weight or a number of pieces was taken over into the sum memory the symbol will
keep flashing until the weight is removed from the pan and the weight < 2d. A new
addition can only be started when the pan was unloaded before.
If there are two scales connected then the weights are added accurate to display.
Example: first item in sum memory is taken from WP1 and the second one from WP2:
1,003 kg
// WP1 with accuracy 1 g
+ 5,15 kg
// WP2 with accuracy 50 g
= 6,153 kg
// total = sum memory
Totalization shall be done also with negative weight values (removing mode). Put weights
on the pan, press
Button. Then remove first weight. Add to Totalization memory.
Press
Button again. Then remove second weight. Add to Totalization memory.
6.5.2.1
Manual Mode
Stable weights ≥ 2d can be accumulated via the
Button pressed briefly. That is
also valid for a number of pieces when there is stability.
The next weight / number of pieces can be accumulated if the scale was unloaded before!
6.5.2.2
Automatic Mode
Stable weights ≥ 2d shall be accumulated automatically if the scale is unloaded before.
That is also valid for a number of pieces if there is stability.
6.5.2.3
Printouts
Min, Max is only printed if ALL is selected in print content [PRINT] - [CONTNT] - [TOTAL]
in menu.
Weights as parameters (= weights are added up):
Printout
Description
N: 2
TOTAL: 1.955 g
MAX: 1.485 g
MIN: 0.470 g
Number of weighing done, here 2
Totalized value
Maximum value
Minimum value
.
If the statistical information shall be cleared press
(Yes) Button briefly.
.
If the statistical information shall not be cleared press
(No) Button briefly.
.
Clearing the counting initialization is done via the
Button pressed briefly or via a
new counting initialization which will cause that the Totalization parameters are
cleared.
6 Application Programs
Compact Scale Puro® Count
Minebea Intec
EN-31