Calibration
Each drive is factory calibrated to its maximum horsepower
rating. Readjust the calibration trimpot settings to
accommodate lower horsepower motors.
All adjustments increase with CW rotation, and decrease with
CCW rotation. Use a non-metallic screwdriver for calibration.
Each trimpot is identified on the printed circuit board.
MIN SPD
The MIN SPD setting determines the minimum speed when
the speed adjust potentiometer is turned full CCW. It is factory
set to zero speed. The minimum speed feature applies only
when the drive is operating in unidirectional mode.
To calibrate MIN SPD:
1. Set the speed adjust potentiometer full CCW.
2. Adjust the MIN SPD trimpot until the motor turns at the
desired minimum speed.
MAX SPD
The MAX SPD setting determines the maximum motor speed
when the speed adjust potentiometer is turned full CW. It is
factory set for maximum rated motor speed.
26
Содержание RG300 Series
Страница 1: ...USER S MANUAL RG300 and RG400 Series SCR Adjustable Speed Regenerative Drives for DC Brush Motors...
Страница 8: ......
Страница 11: ...3 Dimensions Figure 1 RG300UA RG310UA and RG400UA Dimensions...
Страница 12: ...4 Dimensions Figure 2 RG310UA S RG300UA S RG400UA S Dimensions...
Страница 13: ...5 Dimensions Figure 3 RG310A RG300A RG400A and RG310A S RG300A S RG400A S Cased Drive Dimensions...
Страница 15: ...7 Regenerative Drives Figure 4 Four Quadrant Operation...
Страница 22: ...14 Installation Figure 8 Cased Drive Connections Field Output Connections see page 19...
Страница 51: ...43 Figure 23 RG300 and RG400 Series Block Diagram Block Diagram...
Страница 52: ...44 Factory Prewired Connections for Cased Drives Figure 24 Prewired Connections to L1 and L2...
Страница 53: ...45 Factory Prewired Connections Figure 25 Prewired Speed Adjust Potentiometer Connections...
Страница 61: ...Notes 53...
Страница 62: ...Notes 54...