23
Operation
Regenerative brake
Short the INHIBIT terminals to regeneratively brake the
motor. Reopening the INHIBIT terminals causes the motor to
accelerate to set speed.
The INHIBIT terminals bypass both the MIN SPD circuit
and the deceleration circuit. This causes the motor to stop
rapidly when the INHIBIT terminals are shorted. Braking
torque is determined by the opposite-direction torque setting.
Minarik Corporation offers two accessory plug harnesses for
the INHIBIT terminals:
Minarik
®
Part Number
Description
201–0024
Inhibit plug with 18 in. (46 cm) wires
201–0079
Inhibit plug with 36 in. (91 cm) wires
Always twist inhibit wires and separate them from other
power-carrying wires or sources of electrical noise. Use
shielded cable if the inhibit wires are longer than 18 inches
(46 cm). If shielded cable is used, ground only one end of the
shield to earth ground. Do not ground both ends of the
shield.
Содержание RG300 Series
Страница 1: ...USER S MANUAL RG300 and RG400 Series SCR Adjustable Speed Regenerative Drives for DC Brush Motors...
Страница 8: ......
Страница 11: ...3 Dimensions Figure 1 RG300UA RG310UA and RG400UA Dimensions...
Страница 12: ...4 Dimensions Figure 2 RG310UA S RG300UA S RG400UA S Dimensions...
Страница 13: ...5 Dimensions Figure 3 RG310A RG300A RG400A and RG310A S RG300A S RG400A S Cased Drive Dimensions...
Страница 15: ...7 Regenerative Drives Figure 4 Four Quadrant Operation...
Страница 22: ...14 Installation Figure 8 Cased Drive Connections Field Output Connections see page 19...
Страница 51: ...43 Figure 23 RG300 and RG400 Series Block Diagram Block Diagram...
Страница 52: ...44 Factory Prewired Connections for Cased Drives Figure 24 Prewired Connections to L1 and L2...
Страница 53: ...45 Factory Prewired Connections Figure 25 Prewired Speed Adjust Potentiometer Connections...
Страница 61: ...Notes 53...
Страница 62: ...Notes 54...