5-8
6
Press the
key.
• Sensor adjustment starts.
7
Rotate the adjustment screw of the throttle valve to
adjust the pressure so that it becomes the proper
value.
• Proper value of negative pressure: -5.40kPa
Proper value of positive pressure: 15.00kPa
• As the negative pressure changes between ±0.1 kPa, adjust so that the intermediate value may become
the target pressure.
• Status of lamp and buzzer for each pressure value
8
Press the
key.
• The error is released and the negative pressure control starts.
• Pressure is informed with the buzzer and the ink bottle lamp as well as the screen display.
• For the negative pressure, the buzzer stops within the range of ±0.1kPa. For the positive
pressure, the buzzer stops within the range of ±1.0kPa.
Pressure
Ink bottle lamp Buzzer
Positive pressure
Negative pressure
High
~ 8.49
~ -4.75
Sounds
8.50 ~ 9.49
-4.76 ~ -4.85
9.50 ~ 10.49
-4.86 ~ -4.95
10.50 ~ 11.49
-4.96 ~ -5.05
11.50 ~ 12.49
-5.06 ~ -5.15
12.50 ~ 13.49
-5.16 ~ -5.25
13.50 ~ 14.49
-5.26 ~ -5.35
Stops
Proper
value
14.50 ~ 15.49
-5.36 ~ -5.45
Stops
Low
15.50 ~ 16.49
-5.46 ~ -5.55
Stops
16.50 ~ 17.49
-5.56 ~ -5.65
Sounds
17.50 ~ 18.49
-5.66 ~ -5.75
18.50 ~ 19.49
-5.76 ~ -5.85
19.50 ~ 20.49
-5.86 ~ -5.95
20.50 ~ 21.49
-5.96 ~ -6.05
21.50 ~ 22.49
-6.06 ~ -6.15
22.50 ~ 23.49
-6.16 ~ -6.25
23.50 ~
-6.26 ~
• When an error occurs even after you adjusted the pressure, contact your local distributor to call for
service.
* * AD J US T I NG * *
P L EASE WA I T
PRESSURE
: - 5 . 4 0 k P a
( - 5 . 4 0 )
Current pressure
value
Target pressure
value
Ink bottle lamp
P L EASE WA I T
Содержание UJV500-160
Страница 1: ...MIMAKI ENGINEERING CO LTD URL http eng mimaki co jp D202486 15 Original instructions...
Страница 14: ...xiii...
Страница 76: ...2 42...
Страница 176: ...4 46...
Страница 226: ...6 30...
Страница 228: ...NH FW 1 6 MIMAKI ENGINEERING CO LTD 2015...