Replacing consumables
4-35
1
1
1
4
Routine Maintenance
5
Hold the handle at the front of the post cure unit
and open the post cure unit.
• When you open/ close the post cure unit, be sure to hold
the handle to prevent your hand from burn injury and
pinching.
• Open/ close the post cure unit slowly not to break the
mercury lamp.
• During opening/ closing the post cure unit, do not get your
hand off of the handle.
6
Remove the protection cover.
• Remove the screws (for four positions) attached with the
protection cover and then remove the protection cover.
7
Rotate the mercury lamp to replace 90 degrees
and remove it.
8
Set new mercury lamp and fix it by rotating it 90
degrees.
9
Attach the protection cover.
10
Return the post cure unit to the original position and tighten the knob at the right
and the left.
11
Turn the power ON.
• When you turn on the power supply, the machine displaying the
message on the right screen.
12
Refer to P.3-51 “Confirming Machine Information” and clear the usage history for
the replaced post cure lamp.
• If you grasp the mercury lamp strongly, it may
be damaged. Be careful about handling the
mercury lamp.
• There is a specific direction to mercury lamps.
Install mercury lamps with the printed side
facing the media.
POS T CURE UV L AMP
P l e a s e C l e a r
[ ENT ]