- 2-28 -
The front edge and rear
edge are seems nozzle
clogging on the right
pattern, but it works well.
Print the test pattern
•
If the temperature in the water heater or in the UV indication device has not
reached the predetermined value, the following message is indicated. In
this case, printing is disabled. It is enabled when the error indication has
disappeared.
STEPS:
Make sure to set media and the origin.
1
.
Touch the [TEST] in the LOCAL mode.
2.
Touch the [ENTER] to start test printing.
3.
After the printing the test pattern, and then
the printer enters the LOCAL mode.
4.
Check the test patterns.
If any failure occurs, proceed with the next step;
otherwise, terminate the operation.
Checking and Solving Nozzle Clogging
Make test printing to check whether nozzle clogging or other printing failres occurs.
If the finished test pattern shows any sign of abnormal conditions, carry out the cleaning
function.
Normal Pattern
***********
UV NOT READY
************
WATER NOT READY
<< LOCAL >>
** TEST DRAW**
TEST DRAW
NOZZLE CHECK
< ENT >
Black(K)
Cyan(C)
Magenta(M)
Yellow(Y)
Light
Cyan(Lc)
Light
Magenta(Lm)
White(W)
Front edge