Setting the UV Lamp Timer [OFF TIMER]
Set the UV lamp timer.
CONT. IRR. [OFF] .........
The UV lamp is turned off automatically according to setting the time. The
initial setting time is 30 minutes.
CONT. IRR [ON] .............
UV lamp is always lighting on. When turning the lamp off, refer to the “ Turning
off the UV Irradiation Device” to turn the lamp off. (
P.4-7)
STEPS:
1.
Select the [UV LAMP] from the mainte-
nance functions.
Enter the [MAINTENANCE] from the FUNCTION
menu.
2.
Touch the [ENTER].
3.
Touch the JOG [ ] or [ ] to select the
[OFF TIMER].
4.
Touch the [ENTER].
5.
Touch the JOG [ ] or [ ] to set the [CONT.
IRR.] to ‘‘OFF’’.
6.
Touch the [ENTER].
7.
Enter the time by the minutes by touching
the [ ] or [ ] to
8.
Touch the [ENTER].
9.
Touch the [END] to return to the LOCAL
mode.
MAINTENANCE
UV LAMP
<ent>
<<LOCAL>>
UV LAMP
OFF TIMER
<ent>
OFF TIMER
00h 00m
UV OFF TIMER
CONT. IRR.
: OFF
UV LAMP
OFF TIMER
<ent>
UV LAMP
LEVEL CHECK
<ent>
UV OFF TIMER
CONT. IRR.
: ON
UV OFF TIMER
CONT. IRR.
: OFF
OFF TIMER
01h 30m
Содержание UJF-605RII
Страница 22: ... xx ...
Страница 82: ... 2 40 ...
Страница 104: ... 3 22 ...
Страница 114: ... 4 10 ...
Страница 148: ... 5 34 ...
Страница 162: ... A 6 ...
Страница 168: ...A 12 D201670 1 10 27122007 ...
Страница 169: ......
Страница 170: ...Printed in Japan MIMAKI ENGINEERING Co Ltd 2007 EM FW 1 10 ...