- 2.4 -
Front cover /Maintenance cover
Opening/closing the front cover and maintenance cover
•
Keep the front cover and maintenance cover closed during plotting opera-
tion. Opening the cover during plotting interrupts image plotting and disables
continuous processing.
If you open the cover during plotting, the carriage will stop for safety, resulting in abortion of
plotting. In this case, re-start the device and computer following the procedure described below.
Cautions during operation
STEP
1.
When opening the cover during plotting, the
message shown on the right will be displayed.
Stop the drawing.
2.
Stop the data transmission from the computer.
3.
Close the front cover.
4.
Press the [ENTER] key.
5.
The carriage will start to move.
The carriage will carry out a series of performance same as
that taken after turning on the power to the device (i.e., the
predetermined initial performance).
page 2.3
Close a cover
( C O V E R O P E N )
PRESS < ENT > KEY
INITIALIZING
PLEASE WAIT