- 5.13 -
Ink discharge way cleaning [Disway WASH]
The ink discharge way may become clogged by coagulated ink. It must be cleaned at
regular intervals to avoid clogging.
Ink discharge way: Tubing between the cap and the waste ink tank
• When cleaning the ink station and head, be sure to wear the supplied
goggle and gloves since you may get ink in your eyes.
• Do not move the carriage out of the capping station by hand. Use the appro-
priate operation key to move the carriage.
Cleaning tools
•
Cleaning fluid RS for maintenance (SPC-0336)
•
Pipette
•
Glove
STEP
1.
Press the [FUNCTION] key.
2.
Press the [ ] and [ ] key until the display
gives the indication [MAINTENANCE].
3.
Press the [ENTER] key.
[STATION] is displayed.
4.
Press the [ENTER] key.
[CARRIAGE out] is displayed.
5.
Press the [ ] and [ ] key until the display
gives the indication [Disway WASH].
6.
Press the [ENTER] key.
The carriage moves to the platen.
Dry suction starts in cycles consisting of 5 seconds of suction
followed by 10 seconds of pause.
FUNCTION
SET UP
< ENT >
FUNCTION
MAINTENANCE
< ENT >
MAINTENANCE
STATION
< ent >
STATION
MENT : CARRIAGEout
STATION
MENT : Disway WASH
STATION
COMPLETED
: ent
Содержание JV3-130 SP II
Страница 2: ......
Страница 34: ... 1 16 ...
Страница 120: ... 5 32 ...
Страница 130: ... 6 10 ...
Страница 136: ... A 6 ...
Страница 137: ......
Страница 143: ......
Страница 144: ...Printed in Japan MIMAKI ENGINEERING Co Ltd 2004 ...