3-17
Each setting
3
Use
ful Func
tion
Other useful settings
Change settings according to need.
1
Press the
key in the local
mode.
2
Select the [SET UP] by pressing the
or
key.
3
Press the
key.
4
Select an item to be set by pressing the
or
key ,
and press the
key.
• Select with reference to the Table of Setting below.
5
Select a value to be set by pressing the
or
key ,
and press the
key.
• Select with reference to the Table of Setting below.
6
Press the
key twice to finish.
• Set value remains after cutting the power.
Table of Setting
Item
Value
Outline
INK LAYERS
1 to 9 times
Set the number of times for over painting.
Finer drawing can be obtained by conducting the over painting.
REFRESH
Level 0 to 3
Set the refreshing revel for preventing the head from clogging in a
dusty environment.
The larger level number indicates more frequent refreshing times.
Refreshing is not conducted at level=0.
MM/INCH
Millimeter
A unit of set value indicated on the screen is displayed with Millimeter.
Inch
A unit of set value indicated on the screen is displayed with Inch.
UV SCAN ADD
1 to 9 times
Designates the number of times of additional scanning of UV to cure
the edge parts of the image with UV irradiation after completion of the
drawing.
F UNC T I ON
V I EW
< E N T >
FUNCTION
F UNC T I ON
S E T U P
< E N T >
S E T U P
F E E D COMP .
< e n t >
ENTER
ENTER
ENTER
END