![MIMAKI JF-1610 Скачать руководство пользователя страница 107](http://html1.mh-extra.com/html/mimaki/jf-1610/jf-1610_operation-manual_1800229107.webp)
4-39
Replacing UV lamp
4
Daily Maintenance
4
Pull out the exhaust blower Assy
upward.
• After removing the finger screws on the top part of
the exhaust blower Assy, pull out the exhaust
blower Assy.
5
Remove UV lamp cassette.
(1)
Remove the bolt on the front of the UV lamp cassette
using supplied hexagonal wrench.
(2)
Pull off the UV lamp cassette.
6
Place a new UV lamp.
• Fix the bolt on the front of the UV lamp cassette
using supplied hexagonal wrench.
7
Fix the exhaust blower Assy and
tighten the finger screw.
8
Connect the connector of the exhaust blower connecting cable.
9
Fix the front right cover and front left cover and switch ON the
power.
• When the replacement is completed, perform the procedures of P.4-40 "Resetting UV
lamp irradiation duration".
Pull out
Exhaust blower Assy
UV lamp cassette
Remove
Fix
Содержание JF-1610
Страница 32: ...1 14...
Страница 48: ...2 16...
Страница 68: ...3 20...
Страница 128: ...6 6...
Страница 140: ...6 18...
Страница 141: ...D201645 20 29082008...
Страница 142: ...NH FW 2 80 Printed in Japan MIMAKI ENGINEERING CO LTD 2008...