4
ON
Turns ON the laser and unlocks the pendu-
lum to enable self-leveling.
ON
Turns ON the laser but does not unlock the
OFF
Turns OFF the laser and locks the pen-
Using the Laser Level
pendulum (self leveling is disabled). The
to indicate that the projected line are not
level.
NOTE:
The ON mode disables self-
leveling and therefore is not intended for
projecting a level line.
and store the Laser Level in the protective
carrying case.
4.
5.
1. For best results, place the tool on a work surface
that is:
• sturdy
• level (within 4 degrees of true level)
• free of vibrations
• 90° to the work area
2. Turn on the tool.
3. The tool will self-level when placed on surfaces
within 4 degrees of true level when dial is unlocked
and on.
Troubleshooting
If the tool does not turn on:
The tool is ready once the emitted line are continu-
ous and no longer moving on the work surface.
• Ensure battery is installed properly. Fuel gauge
should indicate remaining charge when correctly
installed.
• Ensure battery is charged.
•
ACCURACY FIELD CHECK
NOTICE
Ambient temperature gradients can impact laser
accuracy. For accurate and repeatable results, the
following procedure should be conducted with the
of the working area.
Abusive treatment of the Laser Level, such as exces-
sive impacts from drop, can also lead to deviations
in product accuracy.
Therefore, it is recommended to conduct the Field
Check procedure after any impact or before complet-
ing any critical jobs.
Lanyard Attachments
• Use the embedded magnets to secure the laser
level to steel studs, steel beams, etc.
• Use the keyhole slot to hang the laser level on the
wall with a nail or screw.
• Position the laser and/or wall mount on a stable
surface.
• Use the 1/4"-20 or 5/8"-11 threaded insert to mount
on a tripod.
Fuel Gauge
WARNING
To
age,
reduce
securely
the risk of
mount/attach
injury or dam
the
-
laser before starting an operation. Injury/damage
may occur if the laser falls.
Mounting/Adjusting the Laser Level
The pivot bracket can be used to mount the laser
level in multiple ways:
1. Follow instructions pro-
vided with tool lanyard.
2. The lanyard will create
a secure anchor point
for use.
CAUTION
Use of controls or adjustments or
OPERATION
WARNING
To reduce the risk of injury or tem
on vision, do not
-
look directly into the laser when it is on.
performance of procedures other
-
ous radiation exposure.
NOTICE
Perform the Accuracy Field Check
procedure immediately upon unboxing
of each new Laser Level and before exposure to
jobsite conditions. See "Accuracy Field Check"
for information.
The fuel gauge is displayed continuously when the
tool is ON. When less than 7% of charge is left, 1
light will flash continuously on the fuel gauge until
the tool shuts off.
To signal the end of charge, 1 light on the fuel
gauge will flash 4 times and the tool will not run.
Charge the battery pack.
If the tool becomes too hot, the fuel gauge lights will
flash and the tool will not run. Allow the tool to cool
down.
WARNING
Do not
exceed
maximum capacity marked on the lanyard
label. Exceeding maximum capacity may
result in serious injury or death.
To turn on the laser and unlock the pendulum,
rotate the On/Off dial to the desired position. The
remaining battery life will be displayed.
WARNING
Do not look directly into laser
apertures. Horizontal level line will
immediately be emitted from aperture in the laser
housing.
If the tool cannot achieve a level state (i.e., the
work surface is > 4 degrees off true level), the
laser line will flash rapidly (3 flashes per second).
Relocate or adjust the work surface.
Ensure the tool's internal temperature is within
specified operating ranges. If stored in excessive
heat or cold, allow at least 2 hours to acclimate to
ambient temperature before turning on the tool.
If problem persists, please contact a
MILWAUKEE
®
service facility for support.
Perform the Accuracy Field Check
procedure immediately upon
unboxing of each new Laser Level and before
exposure to jobsite conditions. See "Accuracy
Field Check" for information.
Should any
deviation from listed product accuracy be found,
please contact a
MILWAUKEE
®
service facility.
Failure to do so could result in rejection of warranty
claim.