background image

4

  ON 

Turns ON the laser and unlocks the pendu-

lum to enable self-leveling.

 ON 

Turns ON the laser but does not unlock the 

  

OFF

  Turns OFF the laser and locks the pen-

Using the Laser Level

pendulum (self leveling is disabled). The 

to indicate that the projected line are not 

level.

 

 

NOTE:

 The   ON mode disables self-

leveling and therefore is not intended for 

projecting a level line. 

and store the Laser Level in the protective 

carrying case.

4.

5.

1. For best results, place the tool on a work surface

that is:

• sturdy

• level (within 4 degrees of true level)

• free of vibrations

• 90° to the work area

2. Turn on the tool.

3. The tool will self-level when placed on surfaces

within 4 degrees of true level when dial is unlocked 

and on.

Troubleshooting

If the tool does not turn on:

The tool is ready once the emitted line are continu-

ous and no longer moving on the work surface.

• Ensure battery is installed properly. Fuel gauge

should indicate remaining charge when correctly

installed.

• Ensure battery is charged.

• 

ACCURACY FIELD CHECK

NOTICE

Ambient temperature gradients can impact laser 

accuracy. For accurate and repeatable results, the 

following procedure should be conducted with the 

of the working area.

Abusive treatment of the Laser Level, such as exces-

sive impacts from drop, can also lead to deviations 

in product accuracy.

Therefore, it is recommended to conduct the Field 

Check procedure after any impact or before complet-

ing any critical jobs.

Lanyard Attachments

• Use the embedded magnets to secure the laser

level to steel studs, steel beams, etc.

• Use the keyhole slot to hang the laser level on the

wall with a nail or screw.

• Position the laser and/or wall mount on a stable

surface.

• Use the 1/4"-20 or 5/8"-11 threaded insert to mount

on a tripod.

Fuel Gauge

WARNING

To 

age, 

reduce 

securely 

the risk of 

mount/attach 

injury or dam

the

-

laser before starting an operation. Injury/damage 

may occur if the laser falls.

Mounting/Adjusting the Laser Level

The pivot bracket can be used to mount the laser 

level in multiple ways:

1. Follow instructions pro-

vided with tool lanyard.

2. The lanyard will create

a secure anchor point

for use. 

CAUTION

Use of controls or adjustments or

OPERATION

WARNING

To reduce the risk of injury or tem

on vision, do not

-

look directly into the laser when it is on.

performance of procedures other 

-

ous radiation exposure.

NOTICE

Perform the Accuracy Field Check

procedure immediately upon unboxing 

of each new Laser Level and before exposure to 

jobsite conditions. See "Accuracy Field Check" 

for information.

The fuel gauge is displayed continuously when the 

tool is ON. When less than 7% of charge is left, 1 

light will flash continuously on the fuel gauge until 

the tool shuts off.

To signal the end of charge, 1 light on the fuel 

gauge will flash 4 times and the tool will not run. 

Charge the battery pack.

If the tool becomes too hot, the fuel gauge lights will 

flash and the tool will not run. Allow the tool to cool 

down.

WARNING

Do not 

exceed 

maximum capacity marked on the lanyard 

label. Exceeding maximum capacity may 

result in serious injury or death.

To turn on the laser and unlock the pendulum, 

rotate the On/Off dial to the desired position. The 

remaining battery life will be displayed.

WARNING

Do not look directly into laser 

apertures. Horizontal level line will 

immediately be emitted from aperture in the laser 

housing.

If the tool cannot achieve a level state (i.e., the 

work surface is > 4 degrees off true level), the 

laser line will flash rapidly (3 flashes per second). 

Relocate or adjust the work surface.

Ensure the tool's internal temperature is within 

specified operating ranges. If stored in excessive 

heat or cold, allow at least 2 hours to acclimate to 

ambient temperature before turning on the tool.

If problem persists, please contact a 

MILWAUKEE

®

 

service facility for support.

Perform the Accuracy Field Check 

procedure immediately upon 

unboxing of each new Laser Level and before 

exposure to jobsite conditions. See "Accuracy 

Field Check" for information. 

Should any 

deviation from listed product accuracy be found, 

please contact a 

MILWAUKEE

®

 service facility. 

Failure to do so could result in rejection of warranty 

claim.

Отзывы: