3
Instruction Manual
1.3 GENERAL SPECIFICATIONS
Maximum Capacity Range
20 GPH (76 LPH) to 130 GPH (492 LPH)
Maximum Pressure Range
100 PSIG (7 Bar) to 600 PSIG (41 BAR)
Liquid End Design
Hydraulically Actuated Diaphragm with Mechanically Actuated Refill
System (MARS).
Drive Design
Non-Lost Motion Variable Eccentric Type.
Plunger Diameters
1-1/4”(32mm), 1-3/4”(45mm), 2-1/2”(63mm), 3”(75mm)
Liquid End Materials of
Construction
PVC, 316 SS, Alloy 20.
Steady State Accuracy
±1% of 100% rated flow between 10% and 100% of rated flow
Capacity Adjustment
Micrometer (Standard):
Lockable micrometer is adjustable from
0% to 100% while pump is running or stopped
Electronic (Optional):
Electronic stroke length adjustment from
4-20ma input.
Temperature Limits
Ambient Limit:
130ºF Maximum
0ºF Minimum
Note: Limited by standard lubricants. Modifications are available through
Applications Engineering.
Liquid Temperature Limits:
Plastic Liquid Ends:
20ºF to 140ºF
Metallic Liquid Ends:
20ºF to 190ºF
Suction Pressure Limits
Minimum Internal Pressure:
3 psia (11.5 psi maximum vacuum)
Maximum Suction Pressure:
100 psig at 80ºF and below.
Lubrication
Oil bath drive lubrication.
Paint
Two part epoxy, yellow RAL 1018
SECTION 1 - DESCRIPTION