23
Instruction Manual
B. Installation of New Diaphragm
(Figures 7 & 8)
:
1. Make sure the contoured diaphragm support
surface and O-ring groove machined into
displacement chamber are clean. To prevent
leakage from occurring, be careful not to scratch
the O-ring groove when cleaning.
2. Install the diaphragm into the displacement
chamber with the black rubber side against
the contoured surface of the displacement
chamber. Make sure the diaphragm sealing
bead fits securely in the diaphragm groove of the
displacement chamber. The white teflon-face of
the diaphragm should be facing outward and
visible.
3. Align the two holes in the diaphragm head with the
locating pins (610) in the displacement chamber
and reinstall diaphragm head (1020).
4. Reinstall head bolts (1025), flat washer (1040),
lock washers (1035), and nuts (1030).
5. Tighten bolts firmly in a crisscross pattern.
4.4.5 Removal of Pump Liquid End
(Figures 7 & 8)
MILROYAL
®
G liquid ends are designed to
provide reliable service under normal operating
circumstances and should not require removal
of the liquid end. However, if the need arises, the
following describes the procedure.
BEFORE BEGINNING DISASSEMBLY
PROCEDURES, RELIEVE ALL
PRESSURE FROM SYSTEM, ISOLATE THE LIQUID END FROM ALL
SOURCES OF PROCESS LIQUID WITH APPROPRIATE VALVING, AND
PURGE LIQUID END OF ALL PROCESS LIQUID.
A. Disassembly:
1. Disconnect both the suction inlet and discharge
outlet from the piping system.
2. Drain oil as described in the above “Oil
Replacement” section of this manual.
3. Remove 3- Function Valve assembly as
described in the “Start- Up of Pump Containing
No Oil in Casing and Displacement Chamber”.
4. Remove six displacement chamber bolts (570)
and lock washers (560) which secure liquid end
to pump drive housing.
5. Locate a container under liquid end to catch
approximately 1 pint of oil that will escape during
next step.
6. Gently pull liquid end OFF drive housing
being careful to avoid damage to plunger
(520,
figure 5
) during removal. Drain oil into
waste container.
7. Discard displacement chamber gasket (590).
8. Place the liquid end, diaphragm head up, on
a bench or other clean, flat, convenient work
area.
B. Reassembly:
1. Make sure gasket surface on pump housing
and displacement chamber are clean and free
of markings which could serve as leak paths.
2. Install new displacement chamber gasket (590)
in correct orientation on liquid end.
3. With vent cap (620) at 12 O’clock, gently slide
liquid end over plunger.
4. Reinstall six displacement chamber bolts (570)
and lock washers (560) and tighten securely.
5. Follow procedure for filling pump housing
and liquid end with oil described in “Start- Up
of Pump Containing No Oil in Casing and
Displacement Chamber”.
SECTION 4 - MAINTENANCE