MSSMD 416AE /83371V
(1 of 3)
È
CALIBRATING WATER INLETS
APPLICABILITY: All MILNOR CBWs.
Ê
WATER INLETS
Water inlets on the CBW function in one of two ways:
1.
Constant flow - These inlets remain open so long as Tunnel power is ON
and the CBW is not in a hold condition other than levels low. They provide
the normal operating water and include:
a)
Last Module (fresh water)
b)
R inse Z one (fresh water)
c)
Wash Z one (reuse water)
d)
Trickle Flow to Module 1 (reuse water)
2.
Intermittent flow - These only open as required to satisfy special conditions.
They are:
a)
Flush to Load Scoop (reuse water)
b)
Make-U p Inlet for R euse Tank (fresh water)
c)
Optional Flush E nhance (usually same inlet as "Flush to Load Scoop")
d)
Optional R inse E nhance (fresh water)
e)
Optional Wash E nhance (reuse water)
f)
Optional Fast Fill (fresh water)
72
Содержание 76032
Страница 2: ......
Страница 6: ......
Страница 11: ...Safety and Maintenance 1 7 ...
Страница 27: ......
Страница 29: ......
Страница 43: ...Structural and Drive Components 2 39 ...
Страница 48: ...44 ...
Страница 52: ...BMP910003 91132V Page 1 CBW LOAD CHUTE AND SEAL 48 ...
Страница 56: ...BMP910017 91341V Page 1 CBW ENTRY AND EXIT WATER COLLECTORS 52 ...
Страница 60: ...56 ...
Страница 65: ...61 ...
Страница 69: ...Water and Steam Schematics and Devices 3 65 ...
Страница 80: ...76 ...
Страница 100: ......
Страница 101: ...Chemical Supply Devices 4 97 ...
Страница 103: ...99 ...
Страница 106: ......
Страница 107: ...Control and Sensing Assemblies 5 103 ...
Страница 113: ...109 ...
Страница 114: ...110 ...
Страница 117: ...113 ...