Pellerin Milnor Corporation
2. Attach one end of the manometer to the gauge point
GAC
(the higher pressure). Attach the
other side to the gauge point
GRC
(the lower pressure).
3. Adjust
VR
until the manometer displays the value shown in
. If you cannot
get the required value with
VR
wide open, slowly open
VC
until you get the required value.
4. Look at the burner box pressure light (
) on the status light panel. Slowly turn the dial
SPCA
clockwise:
Fireye
Stop when the light illuminates.
Gyr
Stop when
SPCA
trips and the burner extinguishes. The light should illuminate
momentarily, but this may be too quick to see. Press
and
to reset the flame control.
5. Close
VR
and
VC
fully.
5.3.
Step 3: Main air pressure
BNDGUM01.T02 0000337470 C.2 A.4 5/12/21, 2:30 PM Released
Fireye machines
Select SETUP MODE B (see
). The damper will fully
open.
Gyr machines
Set the damper fully open (D=0). See
1. Look at
. Turn the dial on
SPMA
counterclockwise, to the lowest value
2. Attach one side of the manometer to
GAM
(the lower pressure). Leave the other side open to
the atmosphere (the higher pressure).
3. Adjust
VM
until the manometer displays the test value shown in
4. Look at the burner box pressure light (
) on the status light panel. Very slowly turn the dial
on
SPMA
clockwise:
Fireye machines
Stop when the light illuminates.
Gyr machines
Stop when
SPMA
trips and the burner extinguishes. The light should
illuminate momentarily, but this may be too quick to see. Press
and
to reset the flame
control.
5. Close
VM
fully. The manometer should display the final value shown in
.
5.4.
Step 4A: Regulated pilot gas pressure
BNDGUM01.T03 0000338555 C.2 A.3 3/24/21, 9:39 AM Released
Fireye machines
Select SETUP MODE C (see
). This turns on the
pilot
gas valve
. After about eight seconds, the pilot flame should ignite.
Gyr machines
No action is necessary. The pilot flame should be lit.
Explosion and Fire Hazard —
Improper procedures can release gas.
�
Follow instructions carefully.
1. Look at
. Attach one side of the manometer to
GGP
(the higher pressure).
Leave the other side open to the atmosphere.
2. Remove the cover screw (2) from
VP
.
Set the Heating System—Air Heat Dryer
32
Содержание 5050
Страница 2: ......
Страница 8: ......
Страница 9: ...Safety 1 5 ...
Страница 26: ......
Страница 27: ...Service and Maintenance 2 23 ...
Страница 48: ......
Страница 49: ...Covers and Shipping Brackets 3 45 ...
Страница 62: ......
Страница 63: ...Drive Assemblies 4 59 ...
Страница 78: ......
Страница 79: ...Door Assemblies 5 75 ...