Pellerin Milnor Corporation
,
Selects “RETURN TO AUTOMATIC”
Returns to the run mode
4.2.
Manual method ( Gyr flame control)
BNDGUM01.C06 0000337054 C.2 A.5 3/24/21, 1:08 PM Released
If your machine has a Gyr flame control, run a dry code manually and set the damper
position to 2, as explained below.
Display or Action
Explanation
WAITING FOR LOAD
*****************
The display after the power up sequence.
Accesses the
manual load
menu
SELECT DRY CODE
00
REDRY
Accepts the default dry code 00 and prompts for load size
ENTER LOAD SIZE
0
FULL LOAD
Accepts the default load size (full load).
LOAD DRYER WITH REDRY
Ignore this prompt.
Starts the cycle.
LOADING
This display appears.
00F TIC TOC 000
VP
xx xxxAxxx xxx xxx
This display appears. The VP value alternates with an air value.
Wait for the burner to ignite.
Stops the timer and accesses the manual control panel for temper-
ature, damper and basket rotation.
TICHTOC LDA MVP BSPD
xxx+xxx x
0
x
0x xxxx
+
Sets the damper position. Hold the keys until the damper position
(D) = 2.
TICHTOC LDA MVP BSPD
xxx+xxx x
2
x xxx 000
+
Closes the modulating gas valve (position). Hold the keys until
MVP = 000.
TICHTOC LDA MVP BSPD
xxx+xxx x2x
000
xxxx
The burner will remain on at minimum fire (MVP=000) until commanded to return to automatic.
Start Step 2 here. Upon completion of the steps,
Set the Heating System—Air Heat Dryer
30
Содержание 5050
Страница 2: ......
Страница 8: ......
Страница 9: ...Safety 1 5 ...
Страница 26: ......
Страница 27: ...Service and Maintenance 2 23 ...
Страница 48: ......
Страница 49: ...Covers and Shipping Brackets 3 45 ...
Страница 62: ......
Страница 63: ...Drive Assemblies 4 59 ...
Страница 78: ......
Страница 79: ...Door Assemblies 5 75 ...
Страница 87: ...Air Flow Assemblies 6 83 ...
Страница 102: ......
Страница 103: ...Gas Assemblies 7 99 ...
Страница 114: ......
Страница 115: ...Steam Assemblies 8 111 ...
Страница 120: ......
Страница 121: ...Water Assemblies 9 117 ...
Страница 124: ......
Страница 125: ...Pneumatic Assemblies 10 121 ...