Pellerin Milnor Corporation
Set the Heating System—Air Heat Dryer
BNDGUM01.C01 0000336887 C.2 A.5 4/29/21, 10:11 AM Released
This document applies to gas dryers with an
air heat
burner. See document BNDGUM02 for gas
dryers with a
ratio air
burner.
1.
About the Procedure
BNDGUM01.C10 0000344550 C.2 B.2 5/24/22, 8:31 AM Released
The differences between an
air heat
burner and a
ratio air
burner are important with regard to re-
placement parts and the procedure you use to set or confirm the correct gas and air flows.
Table 1. Current Dryer Models and Burner Types
Burner Type /
Dryer Model
5050TG1_
6450TG1_
6458TG1_
6464TG1_
7676TG1_
8282TG1_
Air Heat
only
optional
standard
standard
Ratio Air
standard
optional
optional
only
only
It can be necessary to set the heating system when the dryer is installed and when components of
the gas train are replaced. You must be a technician trained to do work on gas trains and familiar
with gas train components.
Necessary test equipment includes:
•
A manometer such as Dwyer model 3T294.
•
Tubes and fittings to connect to the taps (test ports) shown herein.
•
In some cases, a fitting with a valve to control the gas released from the tap.
When you set the heating system, you will do a sequence of steps. In most steps you will make
the necessary adjustments to change a measured pressure to match a specified value. Some terms
used in this instruction are:
gas train
the group of valves and related components that controls the flow of natural gas or
propane into the dryer
flame control
an electronic module that monitors and maintains a safe flame. Milnor
®
system
dryers use two brands of flame control:
Fireye
(primarily for the USA and Canada) and
Gyr
(primarily for Europe).
setup mode
a method of performing adjustments that activates the appropriate components for
a given adjustment step. If your machine has the Fireye flame control, you must use the setup
mode to make adjustments.
manual method
a method of performing adjustments that runs a dry code manually and per-
mits you to specify certain conditions for a given adjustment step. If your machine has the
Gyr flame control, you must use the manual method to make adjustments.
manometer
an instrument to measure fluid pressure
Reset button
symbolized
in this procedure, refers to both the physical push button used to
cancel a blinking light on the dryer status light panel and to the reset button on the flame con-
trol (Fireye or Gyr). In this procedure, use whichever reset component applies to the
task.
Signal Cancel button
symbolized
in this procedure, refers to the button on the dryer con-
troller screen used to cancel the operator alarm.
I
BNDGUM01 / 22223
BNDGUM01
0000336888
C.2
5/24/22, 8:33 AM
Released
24
Содержание 5050
Страница 2: ......
Страница 8: ......
Страница 9: ...Safety 1 5 ...
Страница 26: ......
Страница 27: ...Service and Maintenance 2 23 ...
Страница 48: ......
Страница 49: ...Covers and Shipping Brackets 3 45 ...
Страница 62: ......
Страница 63: ...Drive Assemblies 4 59 ...
Страница 78: ......
Страница 79: ...Door Assemblies 5 75 ...
Страница 87: ...Air Flow Assemblies 6 83 ...
Страница 102: ......
Страница 103: ...Gas Assemblies 7 99 ...
Страница 114: ......
Страница 115: ...Steam Assemblies 8 111 ...
Страница 120: ......
Страница 121: ...Water Assemblies 9 117 ...
Страница 124: ......
Страница 125: ...Pneumatic Assemblies 10 121 ...