OM-2221 Page 20
C. Sensing Leads Placement Guidelines For Multiple Arcs
Ref. 804 108-A
BEST
Both sense leads are out of the
current paths.
Both sense leads detect arc volt-
age accurately.
No voltage drop between lead and
trail sense.
Best starts, arcs and most reliable
results.
BETTER
Lead sense is only affected by
weld current from lead.
Trail sense lead is only affected
by weld current from trail.
Due to voltage drops across work
piece, arc voltage may be low,
causing need for deviation from
standard procedures.
BAD
Current flow from lead affects trail
sense.
Current flow from trail affects lead
sense.
Neither sense lead picks up the
correct work voltage, causing
starting and welding arc instability.
Lead
Trail
Lead
Trail
Lead
Trail
Trail
Trail
Lead
Lead
Work
Clamp
Work
Clamp
Trail
Lead
Work
Clamp
Work
Clamp
Trail
Lead
Trail
Lead
Trail
Lead
Welding Power
Source
Welding Power
Source
Welding Power
Source
Welding Power
Source
Welding Power
Source
Welding Power
Source
Remote Voltage
Sense Leads
Remote Voltage
Sense Leads
Remote Voltage
Sense Leads
Remote Voltage Sense Leads
Remote Voltage
Sense Leads
Remote Voltage Sense Leads
Содержание Summit Arc 1000
Страница 14: ...OM 2221 Page 10 ...
Страница 40: ...OM 2221 Page 36 SECTION 8 ELECTRICAL DIAGRAMS Figure 8 1 Circuit Diagram For 460 And 575 VAC Input Models ...
Страница 41: ...OM 2221 Page 37 224 360 B ...
Страница 42: ...OM 2221 Page 38 Figure 8 2 Circuit Diagram For 400 VAC Input Models ...
Страница 43: ...OM 2221 Page 39 224 361 B ...
Страница 49: ...Notes ...
Страница 50: ...TM 216 869 Page 46 Dynasty 350 700 Maxstar 350 700 Notes ...