OM-2221 Page 12
SECTION 4
−
INSTALLATION
4-1. Important Information Regarding CE Products (Sold Within The EU)
A. Information On Electromagnetic Fields (EMF)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974
−
1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure
information.
S
The EMF assessment on this equipment was conducted at 0.5 meter.
S
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
ce-emf 1 2010-10
B. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low
−
voltage supply system. There may be potential difficulties in ensuring electromagnetic compatibility in those locations, due to
conducted as well as radiated disturbances.
IEC/TS 61000
−
3
−
4 may be used to guide the parties concerned by the installation of arc welding equipment with an input current above 75 Amps
in a low-voltage network.
ce-emc 5 2010-10
4-2. Serial Number And Rating Label Location
The rating information for the power source is located on the front or the rear of the machine. Use the rating labels to determine input power require-
ments and/or rated output. The serial number is located on the front of the machine, for future reference, write serial number in space provided on
back cover of this manual.
4-3. Specifications
AC or DC
Rated Output
Voltage
Range in
CV Mode
Amperage
Range in
CC Mode
Max
Open-Circuit
Voltage
IP
Rating
RMS Amps Input at Rated Load Output,
3-Phase at NEMA Load
Voltages and Class I Rating
KVA
KW
380/400/415 V
(50/60 Hz)
460 V
(60 Hz)
500 V
(50/60 Hz)
575 V
(60 Hz)
1000 A at 44 V,
100% Duty Cycle;
1250 A at 44 V,
60% Duty Cycle
25
−
44 V
250
−
1250 A
71 V
21S**
143
(3*)
124
(3*)
114
(3*)
100
(3*)
98
(2.37*)
53
(0.95*)
*While idling
** This equipment is designed for indoor use and is not intended to be used or stored outside.
Содержание Summit Arc 1000
Страница 14: ...OM 2221 Page 10 ...
Страница 40: ...OM 2221 Page 36 SECTION 8 ELECTRICAL DIAGRAMS Figure 8 1 Circuit Diagram For 460 And 575 VAC Input Models ...
Страница 41: ...OM 2221 Page 37 224 360 B ...
Страница 42: ...OM 2221 Page 38 Figure 8 2 Circuit Diagram For 400 VAC Input Models ...
Страница 43: ...OM 2221 Page 39 224 361 B ...
Страница 49: ...Notes ...
Страница 50: ...TM 216 869 Page 46 Dynasty 350 700 Maxstar 350 700 Notes ...