OM-2221 Page 19
B. Remote Voltage Sensing Leads Placement Guidelines For A Single Arc (Required)
Ref. 804 108-A
BEST
Sense leads are out of the current
paths.
Sense leads detect arc voltage ac-
curately.
Best starts, arcs and most reliable
results.
BAD
Sense lead is affected by weld
current.
Due to voltage drops across work
piece, arc voltage may be low,
causing need for deviation from
standard procedures.
Work
Clamp
Remote Voltage
Sense Leads
Work
Clamp
Welding Power
Source
Welding Power
Source
Remote Voltage
Sense Leads
Содержание Summit Arc 1000
Страница 14: ...OM 2221 Page 10 ...
Страница 40: ...OM 2221 Page 36 SECTION 8 ELECTRICAL DIAGRAMS Figure 8 1 Circuit Diagram For 460 And 575 VAC Input Models ...
Страница 41: ...OM 2221 Page 37 224 360 B ...
Страница 42: ...OM 2221 Page 38 Figure 8 2 Circuit Diagram For 400 VAC Input Models ...
Страница 43: ...OM 2221 Page 39 224 361 B ...
Страница 49: ...Notes ...
Страница 50: ...TM 216 869 Page 46 Dynasty 350 700 Maxstar 350 700 Notes ...