background image

EnPak_warr 2010

01

Effective January 1, 2010

(Equipment with a serial number preface of MA or newer)

This limited warranty supersedes all previous EnPak warranties and is exclusive with no other

guarantees or warranties expressed or implied.

LIMITED WARRANTY 

 Subject to the express terms

and conditions set forth below, Miller Electric Mfg. Co.
(“Miller”), of Appleton, Wisconsin (USA), warrants to the
original retail purchaser of new EnPak equipment (sold
after the effective date of this Limited Warranty) that
such equipment is free from defects in materials and
workmanship when shipped by Miller.
For warranty claims received by Miller within the
applicable warranty periods described below, Miller will
repair or replace any warranted equipment, parts or
components that fail due to defects in material or
workmanship or refund the purchase price for the
equipment.  Miller must be notified in writing within thirty
(30) days of such defect or failure, at which time Miller
will provide instructions on the warranty claim
procedures to be followed.
Miller shall honor warranty claims on warranted
equipment in the event of such failure within the
applicable warranty periods. All warranty time periods
start on the delivery date of the equipment to the original
end

user purchaser, and shall not commence more

than one (1) year following that date on which the
equipment is shipped to a North American distributor, or
more than eighteen (18) months following that date on
which the equipment is shipped to an international
distributor.

1.  1 Year — Parts and Labor Unless Otherwise

Specified
* Engine Driven Generators (NOTE: engines are

warranted separately by the engine

manufacturer.)

* Field options (NOTE: field options are covered

for the remaining warranty period of the product

they are installed in, or for a minimum of one year

— whichever is greater.)

2.  90 Days — Parts

* Remote Controls
* Accessory (Kits)
* Replacement Parts (No labor)
* Canvas Covers

This Limited Warranty shall not apply to:
(i) consumable components, such as contactors, relays
or parts that fail due to normal wear and use; (ii) items
furnished by Miller, but manufactured by others, such as
engines and trade accessories (these items are
covered by the manufacturer’s warranty, if any); and (iii)
equipment that has been modified by any party other
than Miller, or equipment that has been improperly
installed, improperly operated or misused based upon
industry standards; or equipment which has not been
used and maintained in accordance with Miller’s
specifications; or equipment which has been operated
outside of Miller’s specifications for the equipment.
Miller products are intended for purchase and use by
commercial/industrial users and persons trained and
experienced in the use and maintenance of industrial
equipment.
In the event of a warranty claim covered by this Limited
Warranty, the exclusive remedies shall be, at Miller’s

sole discretion: (i) repair; or (ii) replacement; (iii) where
authorized in writing by Miller in appropriate cases, the
reasonable cost of repair or replacement at an
authorized EnPak service facility; or (iv) payment of (or
credit for) the purchase price (less reasonable
depreciation based upon actual use) upon return of the
equipment at the warranty claimant’s risk and expense.
Miller’s option of repair or replacement will be F.O.B.,
Appleton, Wisconsin; (USA), or F.O.B. an EnPak
authorized service facility designated in writing by Miller.
No compensation or reimbursement for transportation
costs of any kind will be allowed.

TO THE GREATEST EXTENT PERMITTED BY
APPLICABLE LAW, THE REMEDIES PROVIDED
HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES APPLICABLE TO THE ENPAK
EQUIPMENT. IN NO EVENT SHALL MILLER
BECOME LIABLE FOR DIRECT, INDIRECT,
SPECIAL, PUNITIVE, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LOSS
OF PROFIT OR LOST BUSINESS OPPORTUNITY),
WHETHER BASED IN CONTRACT, TORT OR ANY
OTHER LEGAL THEORY.  IN NO EVENT SHALL
MILLER BECOME OBLIGATED TO PAY MORE ON
ANY WARRANTY CLAIM THAN THE PURCHASE
PRICE ACTUALLY PAID BY THE ORIGINAL RETAIL
PURCHASER.

THIS LIMITED WARRANTY IS MADE IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND/OR FITNESS FOR A
PARTICULAR PURPOSE, OR ANY OTHER
WARRANTY OR GUARANTEE ARISING BY
OPERATION OF LAW.  ANY WARRANTY NOT
EXPRESSLY PROVIDED HEREIN, IMPLIED
WARRANTY, GUARANTY AND ANY OR
REPRESENTATION REGARDING THE
PERFORMANCE OF THE EQUIPMENT, AND ANY
REMEDY FOR BREACH OF CONTRACT, IN TORT,
OR ANY OTHER LEGAL THEORY WHICH, BUT FOR
THIS PROVISION, MIGHT ARISE BY IMPLICATION,
OPERATION OF LAW, CUSTOM OF TRADE, OR
COURSE OF DEALING ARE EXCLUDED AND
DISCLAIMED BY MILLER.

Some states in the United States of America do not
allow limitations of how long an implied warranty lasts,
or the exclusion of incidental, indirect, special or
consequential damages, such the above limitations and
exclusions may not apply to you. This warranty provides
specific legal rights.  Other rights may be available to
you, but may vary from state to state.

In Canada, legislation in some provinces provides for
certain additional warranties or remedies other than as
stated herein, and to the extent that they may not be
waived, the limitations and exclusions set out above
may not apply. This Limited Warranty provides specific
legal rights, and other rights may be available, but may
vary from province to province.

 

ENPAK

 

 EQUIPMENT

LIMITED WARRANTY

Visit our website at

www.EnPak.com

to locate an EnPak supplier.

Содержание EnPak Mechanic OM-240 113H

Страница 1: ...EnPakt Mechanic Series Description OM 240 113H 2010 04 Visit our website at www EnPak com File Mobile Utility Mobile Utility Unit With Air Compressor Hydraulic Pump And Auxiliary Power Capability...

Страница 2: ...oducts continue the tradition They re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929 This Owner s Manual is designed to hel...

Страница 3: ...1 Auxiliary Power And Engine Specifications 16 4 2 Air Compressor Specifications 16 4 3 Hydraulic Specifications Models With Hydraulic Power Source 16 4 4 Sound Level Table 16 4 5 Dimensions Weights...

Страница 4: ...stem Integration 41 11 2 Hydraulic Hose Connections 43 11 3 Priming Hydraulic Pump 44 11 4 Load Sense Line Bleeding Closed Center Systems Only 45 SECTION 12 ENGINE PREPARATION 46 12 1 Connecting the B...

Страница 5: ...is a high risk of unavoid able or accidental contact with the workpiece or ground For these conditions use the following equipment in order presented 1 a semiautomaticDC constant voltage wire welder 2...

Страница 6: ...o through small cracks and openings to adjacent areas D Watch for fire and keep a fire extinguisher nearby D Be aware that welding on a ceiling floor bulkhead or partition can cause fire on the hidden...

Страница 7: ...can injure D Keep away from moving parts such as fans belts and rotors D Keep all doors panels covers and guards closed and securely in place D Stop engine before installing or connecting unit D Have...

Страница 8: ...TS can injure D Keep away from moving parts such as fans belts and rotors D Keep all doors panels covers and guards closed and securely in place D Keep hands hair loose clothing and tools away from mo...

Страница 9: ...TS can burn D Do not touch hot compressor or air system parts D Allow cooling period before working on equip ment D To handle hot parts use proper tools and or wear heavy insu lated welding gloves and...

Страница 10: ...D Keep high frequency source doors and panels tightly shut keep spark gaps at correct setting and use grounding and shielding to minimize the possibility of interference ARC WELDING can cause interfer...

Страница 11: ...General Indus try Title 29 Code of Federal Regulations CFR Part 1910 Subpart Q and Part 1926 Subpart J from U S Government Printing Office Super intendentof Documents P O Box 371954 Pittsburgh PA 152...

Страница 12: ...e t l commande si l appareil en est quip D Des pr cautions de s curit suppl mentaires sont requises dans des environnements risque comme les endroits humides ou lorsque l on porte des v tements mouill...

Страница 13: ...rmes de s curit D Porter des lunettes de s curit avec crans lat raux m me sous votre casque D Avoir recours des crans protecteurs ou des rideaux pour prot ger les autres contre les rayonnements les bl...

Страница 14: ...cher le c ble n gatif en premier lieu Le rebrancher en dernier lieu D Les sources d tincelles flammes nues cigarettes et autres sources d inflammation doivent tre maintenues l cart des batteries Ces d...

Страница 15: ...nominal ou la capacit de la pompe hydraulique ou de tout quipement du circuit hydraulique Concevoir le circuit hydraulique de telle sorte que la d faillance d un composant hydraulique ne risque pas d...

Страница 16: ...er un accident mat riel ou corporel D Avant d intervenir sur le circuit d air comprim couper l alimentation lectrique verrouiller et tiqueter l appareil d tendre la pression et s assurer que le circui...

Страница 17: ...er l appareil proximit de pro duits inflammables D Ne pas surcharger l installation lectrique s assurer que l ali mentationest correctement dimensionn e et prot g e avant de mettre l appareil en servi...

Страница 18: ...ec tronique sensible tel que les ordinateurs et l quipementcommand par ordinateur tel que les robots D Veiller ce que tout l quipement de la zone de soudage soit compatible lectromagn tiquement D Pour...

Страница 19: ...926 Subpart J from U S Government Printing Office Super intendentof Documents P O Box 371954 Pittsburgh PA 15250 7954 phone 1 866 512 1800 there are 10 OSHA Regional Offices phone for Region 5 Chicago...

Страница 20: ...ntinuous Kubota D1105 E3B 3 Cylinder 27 7 HP Liquid Cooled Diesel Engine w Electronic Governor 4 2 Air Compressor Specifications Compressor Type Air Output At Effective Working Pressure Pressure Safet...

Страница 21: ...5 Do not exceed tilt angles or engine could be damaged or unit could tip Do not move or operate unit where it could tip Do not operate suspended from lifting eye Weight 955 lb 433 kg Fully Equipped 76...

Страница 22: ...ILIARY POWER IN KILOWATTS 0 0 1 0 2 0 3 0 4 0 5 0 6 0 U S GAL HR 1 80 1 60 1 40 1 20 1 00 0 80 0 60 0 40 0 20 0 00 Optional EnVertert Auxiliary Power Auxiliary Power Compressor U S GAL HR 1 80 1 60 1...

Страница 23: ...not turn on place the EnPak in high speed This will bring the output of the generator up to the normal 120 VAC or 240 VAC level and the machine that is plugged into the generat or should work normall...

Страница 24: ...ssor Curves CFM VS ENGINE RPM CFM VS PSI ENGINE SPEED RPM PRESSURE PSI CUBIC FEET PER MINUTE CFM CUBIC FEET PER MINUTE CFM 24 32 39 43 43 42 41 40 1800 2600 3200 3600 0 5 10 15 20 25 30 35 40 45 50 10...

Страница 25: ...r 400 PSID 27 6 bar Open Center 200 PSID 13 8 bar 0 500 1000 1500 2000 2500 3000 3500 0 0 2 0 4 0 6 0 8 0 10 0 12 0 14 0 16 0 18 0 20 0 PRESSURE PSI FLOW GPM 0 500 1000 1500 2000 2500 3000 3500 PRESSU...

Страница 26: ...system to monitor oil level Open top cover and service side door 1 Oil Dipstick 2 Oil Fill 3 Coolant Overflow Bottle 4 Radiator Cap Fuel Be sure fuel connections are made and tight Be sure fuel tank u...

Страница 27: ...rfill 1 Air Compressor Oil Fill Cap Hand tighten oil fill cap Using excess force can damage o ring 2 Air Compressor Oil Sight Hole The unit is shipped with oil in the com pressor reservoir Minimum oil...

Страница 28: ...en gine is locked in high speed 8 Engine Off Push Button Press when engine is running to stop en gine 9 Compressor On Off Push Button When engine is running press twice to turn compressor on or off Wh...

Страница 29: ...cates the compressor has an over pres sure error OVErSPEEd Indicates an engine over speed error LOW OIL Indicates a low oil pressure condition in the engine NoCHARGE Indicates an alternator problem Hi...

Страница 30: ...on the service pan el do not function 2 Engine Speed Switch High position is 3600 RPM and is used when generator power is required or the compressor or hydraulic system will be loaded Low position is...

Страница 31: ...ry voltage NoCHARGE Check alternator terminal L 1 Long 4 Short High coolant temperature HiTEMP 1 Check coolant temperature switch 1 Long 6 Short High coolant temperature HiTEMP2 Check coolant temperat...

Страница 32: ...pressure is reduced below 175 psi the compressor controls reset and resume nor mal operation If pressure reaches 200 psi the com pressor clutch will disengage and shut down Once the compressor pressur...

Страница 33: ...OM 240 113 Page 29 SECTION 8 MAINTENANCE 8 1 Maintenance Label When working on unit always move Manual Remote switch on Service Panel to Manual position to prevent remote starting...

Страница 34: ...important start up service and storage information Service equipment more often if used in severe conditions Recycle fluids n Check Z Change Clean If unit is so equipped Reference Every 8 Hours Sectio...

Страница 35: ...f cover and housing Remove cover and dump out dust Remove element s Wipe dust from inside cover and housing with damp cloth Reinstall safety element if present Reinstall cover Do not clean housing wit...

Страница 36: ...line if cracked or worn Install new filters Wipe up any spilled fuel Start engine and check for fuel leaks Stop engine tighten connec tions as necessary and wipe up fuel To reset engine maintenance h...

Страница 37: ...8 6 Engine Sensors And Governor Locations 805 452 A 805 444 A 1 Coolant Temperature Sensor 2 Actuator Governor 3 Engine Speed Sensor 4 Coolant Temperature Shutdown Switch 5 Oil Pressure Sensor 6 Alte...

Страница 38: ...filter Drain compressor oil while compressor is still warm Remove fill cap and plug from oil drain fit ting and drain oil into a suitable container Reinstall oil drain plug Remove filter by turning f...

Страница 39: ...y Check battery voltage Check Manual Remote switch on Service Panel Check to ensure crane power switch and safety interlock are working see Section 8 4 Have Factory Authorized Service Agent check Remo...

Страница 40: ...zed Service Agent check air compressor control circuit and clutch Air compressor stops after short period of operation Automatic shutdown stops compressor if compressor temperature is too high or over...

Страница 41: ...ic oil viscosity too high See Section 11 1 for correct fluid viscosity recommendations at spe cific ambient temperatures Slow crane operation unit remains at low speed Open Center systems No trigger s...

Страница 42: ...at specific ambient temperatures Fast outrigger operation Differential pressure setting of pump load sense set too high Have Factory Authorized Service Agent check setting and correct as necessary Hy...

Страница 43: ...nd comply with all DOT and other applicablecodes NOTICE Do not install unit where air flow is restricted or engine may overheat See Section 10 3 for mounting information See Section 4 5 for dimensions...

Страница 44: ...t on flat surface or use cross supports to support base Secure unit with mounting brack ets 3 1 2 in Bolt And Washer Minimum Not Supplied 4 3 8 16 x 1 in Screws Supplied To Bolt Unit In Place Remove h...

Страница 45: ...angle must be considered A suction strainer is not recommended by the hydraulic pump manufacturer If a suction strainer is used diligent preventive maintenance is required to prevent the strainer fro...

Страница 46: ...60 ft lb 4 Applicable only to closed center system Connection JIC 37 4 7 16 20 torque 12 ft lb 5 Based on 10 15 fps velocity The line should connect directly back to reservoir through a return filter...

Страница 47: ...ammable Do not work on hydraulics near sparks or flames do not smoke near hydraulic fluid Route all hoses away from hot sharp or moving parts Check all connections and hoses for damage leaks and wear...

Страница 48: ...kwise fully opens proportional valve On Service Panel place Manual Remote switch in the Manual position Place the Fuel Pump switch in the Off position Crank the engine for 10 seconds pause crank again...

Страница 49: ...ar the pump This is accomplished us ing the push activated valve on the load sense line Remove the spout cap from the valve Attach a 3 16 in 4 7 mm tube to the spout and drain to a suit able container...

Страница 50: ...m hot sharp or moving parts Connect negative cable last 1 Battery Cable Strain Relief 2 EnPak Engine Block 3 Starter Route cables from vehicle bat tery through strain relief Connect positive cable to...

Страница 51: ...eep away from exhaust out let Do not point exhaust pipe to ward any compressed gas tank Point exhaust pipe in desired di rection but always away from di rection of travel 1 Exhaust Pipe 2 Clamp 3 Nut...

Страница 52: ...leaks and wear 1 Fuel Pickup Connection 2 Fuel Return Connection Select hose rated to SAE 30R7 and certified to section 2754 a 1 C of the California Air Re sources Board 2006 Emission Regulations Fuel...

Страница 53: ...inants The reservoir should be ASME Code for 200 psi working pressure A drain valve should also be installed for draining water and contaminants The reservoir must have a safety relief valve installed...

Страница 54: ...onnections 805 443 A 287 097 Stop engine and release air pressure before servicing compressor 1 Air Compressor Connection Connect and secure hose After hand tighteningconnections tight en 2 to 3 full...

Страница 55: ...iver in front of the air oil separator filter The safety valve should be tested frequently at regu lar intervals to ensure it is in good working order The valve is type tested and leaded It is spring...

Страница 56: ...238027 between re mote panel and RC12 2 Crane Remote Connection Receptacle RC13 NOTICE Connect to this recept acle only when EnPak is equipped with hydraulic power source used to power a hydraulic cra...

Страница 57: ...n If a GFCI receptacle is in stalled it must be a Miller recommended GFCI recept acle see Parts List The generator does not provide usable power at engine idle speed 1800 rpm Other GFCI receptacles ca...

Страница 58: ...onnected Supplementary protector CB2 pro tects the optional EnVerter power supply from overload when a 120 VAC load is connected Supplementary protector CB3 pro tects the generator winding from overlo...

Страница 59: ...Notes 16 Gauge 063 in 22 Gauge 031 in 24 Gauge 025 in 20 Gauge 037 in 18 Gauge 050 in 14 Gauge 078 in 1 8 in 125 in 3 16 in 188 in 1 4 in 25 in 5 16 in 313 in 3 8 in 375 in 1 2 in 5 in MATERIAL THICKN...

Страница 60: ...OM 240 113 Page 56 SECTION 16 DIAGRAMS Figure 16 1 EnPak Circuit Diagram...

Страница 61: ...OM 240 113 Page 57 241 852 F...

Страница 62: ...PSI P IC P O T O IL TH ERM O STAT COMPONENT IDENTIFIER LEGEND P PC PRO PORTIO N AL CO N TROL P HC HEATER CONTROL P HTC HEATERTHERM OSTAT CONTROL P PRV PROPORTIONAL RELIEF VALVE P USV UNLOAD SOLENOID...

Страница 63: ...OM 240 113 Page 59 238 945 B1 Figure 16 3 Hydraulic Circuit Diagram Page 1 Models With Hydraulic Power Source...

Страница 64: ...OM 240 113 Page 60 238 945 B2 Figure 16 4 Hydraulic Circuit Diagram Page 2 Typical Open Center Configuration Models With Hydraulic Power Source...

Страница 65: ...OM 240 113 Page 61 Figure 16 5 Hydraulic Circuit Diagram Page 3 Typical Closed Center With Load Sense Configuration Models With Hydraulic Power Source 238 945 B3...

Страница 66: ...OM 240 113 Page 62 242 500 C Figure 16 6 EnPak Truck Wiring Diagram...

Страница 67: ...ock and static electricity hazards Also see AWS Safety Health Fact Sheet No 29 Grounding of Portable And Vehicle Mounted Welding Generators 1 EquipmentGrounding Terminal On Front Panel 2 Grounding Cab...

Страница 68: ...ve load and requires a constant amount of power 2 Non Resistive Load Equipment with a motor is a non re sistive load and requires approxi mately six times more power while starting the motor than when...

Страница 69: ...Home Equipment Rating Starting Watts Running Watts Stock Tank De Icer 1000 1000 Grain Cleaner 1 4 HP 1650 650 Portable Conveyor 1 2 HP 3400 1000 Grain Elevator 3 4 HP 4400 1400 Milk Cooler 2900 1100...

Страница 70: ...HP 6000 1500 1 1 2 HP 8200 2200 2 HP 10500 2800 Electric Chain Saw 1 1 2 HP 12 in 1100 1100 2 HP 14 in 1100 1100 Electric Trimmer Standard 9 in 350 350 Heavy Duty 12 in 500 500 Electric Cultivator 1...

Страница 71: ...must be at least twice the motor s running amperage kVA HP x HP x 1000 Volts Starting Amperage Example Calculate starting amper age required for a 230 V 1 4 HP mo tor with a motor start code of M Vol...

Страница 72: ...k to electric utility when service is re stored Install correct switch customer supplied Switch rating must be same as or greater than the branch overcurrent protection 3 Fused Disconnect Switch Insta...

Страница 73: ...0 15 40 4800 112 34 62 19 37 11 45 5400 100 30 62 19 50 6000 87 26 50 15 Conductor size is based on maximum 2 voltage drop Cord Lengths for 240 Volt Loads If unit does not have GFCI receptacles use GF...

Страница 74: ...n and not available unless listed Unit shown is fully equipped Some parts may not be applicable on units without hyrdraulic power source 55 56 58 59 60 61 53 54 1 2 3 4 5 6 7 8 9 10 11 12 13 57 62 63...

Страница 75: ...OM 240 113 Page 71 242 707 A 37 38 39 40 41 42 35 36 15 16 17 18 19 20 21 22 23 24 25 26 27 28 30 33 34 29 43 44 45 46 47 32 31 48 50 51 52 49...

Страница 76: ...ce Lid Pivot 1 27 239330 Foam Acoustical Top Cover Left 1 28 Label Circuit Diagram Order by Model and Serial No 1 29 239033 Cover Top 1 30 194320 Latch Lever Flush Trigger 4 31 189975 Hinge Door Acces...

Страница 77: ...5 239325 Foam Acoustical Service Side Door 1 66 239324 Foam Acoustical Service Side Panel 1 67 239046 Baffle Service Door 1 68 239322 Foam Acoustical Service Door Baffle 2 69 239036 Door Side Service...

Страница 78: ...113 Page 74 1 Hardware is common and not available unless listed 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 242 678 A 33 34 Figure 18 2 Controls Remote Assem...

Страница 79: ...d X 1 125 Mtg Hole 4 21 173734 Link Jumper 2 22 1T 172661 Block Stud Connection 6 Position 1 23 CB2 083432 Supplementary Pro Man Reset 1p 10a 250vac Frict 1 24 CB3 093996 Supplementary Pro Man Reset 1...

Страница 80: ...atic Proportional Control Ap 40 Includes 1 3 P USV 242848 Valve Solenoid Unload Pneumatic 12vdc 10w 2wno 1 4 P HC HTC242846 Heater Control Pneumatic 45w 120v W Thermostat N 1 5 P PRV 242847 Valve Reli...

Страница 81: ...4 Hose Assy Oil Compressor 8 Thermostat To Filter 1 34 239555 Ftg Stl 90 Deg 1 2 bspp M S X Jic 8 M 1 35 239558 Ftg Stl Adapter 1 2 bspp M X Jic 8 M 1 36 P OT 239564 Thermostat Oil Air Compressor 71 D...

Страница 82: ...Hyd Proportional 12vdc 2way Nc 1 7 239027 Ftg Stl Elbow 90 Sae 12 M S X Jic 12 M 1 8 239011 Hose Assy Hyd Pressure 12 1 9 239015 Ftg Stl Elbow 90 Sae 4 M S X Jic 4 M 2 10 239022 Ftg Stl Sae 16 M S X S...

Страница 83: ...Assy Hyd Pressure 12 1 9 239106 Ftg Stl Plug Sae 4 M 1 10 239022 Ftg Stl Sae 16 M S X Sae 16 M 1 11 239306 Pulley Micro v 8 Rib 5 938 Pd 1 12 239308 Tensioner Belt W Pulley 8 Rib 1 13 239316 Belt Micr...

Страница 84: ...hroud 1 2 187120 Cap Radiator Pressure 14lb 1 3 243021 Label Warning Moving Parts Can Cause Injury 2 4 243022 Label Warning Steam And Hot Coolant Can Burn 1 5 239819 Guard Fan 1 6 239313 Hose Radiator...

Страница 85: ...4 Npt F 1 29 240445 Ftg Brs Barbed M 1 2 Tbg X 1 4 Npt M 1 30 239317 Ftg Brs Union 1 8 Npt 2 31 073432 Ftg Hose Brs Barbed M 3 16 Tbg X 1 8 Npt 1 32 053525 Ftg Hose Brs Barbed M 5 16 Tbg X 1 8 Npt 1 3...

Страница 86: ...Rotor Generator 1 7 239009 Fan Rotor Gen 1 8 239019 Bearing Ball Rdl Sgl Row 1 000 X 2 047 X 591 1 241851 Key Stl 250 X 250 X 750 Form A 1 9 244932 Key Stl 187 X 250 X 687 1 10 238950 Stator Generato...

Страница 87: ...Engine Kubota D1105 1 27 196484 Screw M 8 1 2 x 55 Hex Hd pln 8 8 Pln Full Thd 3 28 240463 Hose Sae 375 Id X 620 Od X 4 000 4 29 247255 Bracket Support Pump Mtg Flange 1 Use Loctite 271 MILLER Part No...

Страница 88: ...1 5mm W P 3 11mm Od Tin Brass 2 237894 Seal Conn Metri pack Dark Red 2 PLG 8 237895 Conn Pack 3p 1row Plg Yazaki 1 PLG 7 237897 Conn Amp Econoseal 2p 1row Plug 1 PLG 6 237901 Conn Body 2 Pin Sealed Su...

Страница 89: ...re intended for purchase and use by commercial industrial users and persons trained and experienced in the use and maintenance of industrial equipment In the event of a warranty claim covered by this...

Страница 90: ...ur personal records Always provide Model Name and Serial Style Number Visit www EnPak com to locate an EnPak supplier Options and Accessories Service and Repair Replacement Parts Training Schools Vide...

Отзывы: