OM-240 113 Page 23
5-3. Compressor Prestart Checks
805 444-A
.
The compressor is equipped with high
oil temperature shutdown. High oil
temperature can be caused by low oil
or hot air recirculation.
.
Do not open oil fill cap until unit has
been off for 10 minutes. Do not open
while running.
NOTICE
−
Do not mix oil types. Do not
overfill.
1
Air Compressor Oil Fill Cap
Hand tighten oil fill cap. Using excess
force can damage o
−
ring.
2
Air Compressor Oil Sight Hole
The unit is shipped with oil in the com-
pressor reservoir. Minimum oil level is half
way up the sight hole. Maximum oil level is
in threaded area of oil fill pipe. Check level
frequently. If oil needs to be added, be
sure unit is off for 10 minutes before re-
moving fill cap.
.
Minimum com-
pressor oil level
is half way up
the sight hole.
Maximum oil
level is in
threaded area
of oil fill pipe.
1
2