OM-216 869 Page 72
B. Lockout Levels
Before activating lockout levels, be
sure that all procedures and parame-
ters are established. Parameter adjust-
ment is limited while lockout levels are
active.
Level 1
Remote amperage control is not avail-
able in level 1.
TIG Output Selection
If either the TIG HF Impulse or TIG Lift Arc
process (see Section 5-7) was active when
lockout level 1 was activated, the operator
can choose between RMT STD (Remote
Standard) or RMT 2T HOLD (Remote 2T
Hold) (see Section 5-9). The On function is
also available if TIG Lift Arc was active.
Stick Output Selection
If the Stick process was active when lock-
out level 1 was activated, the operator can
choose between RMT STD or On.
When parameter change or selection is lim-
ited by lock level 1, [LOCK][LEV1] is dis-
played as a reminder.
Level 2
Remote amperage control is not avail-
able in level 2.
Includes all the functions of level 1 plus
Memory, Polarity and Process Selection
(see Sections 5-6 and 5-7).
When parameter change or selection is lim-
ited by lock level 2, [LOCK][LEV2] is dis-
played as a reminder.
Level 3
Remote amperage control is not avail-
able in level 3.
Includes all the functions of levels 1 and 2
plus the following:
+
10% adjustment of preset TIG or Stick
Weld Amps
Select desired process, TIG or Stick, and
use Encoder control to adjust am/
−
10% of preset amperage value, up to the
limits of the machine. If operator tries to go
beyond the
10%, the amperage (right) me-
ter will display [LOCK][LEV3] as a reminder.
Pulser ON/Off Control
Gives operator the ability to turn on/off the
Pulser control.
When parameter change or selection is lim-
ited by lock level 3, [LOCK][LEV3] is dis-
played as a reminder.
Level 4
Includes all the functions of levels 1, 2, and
3 plus the following:
Remote Amperage Control
Allows operator to use remote amperage
control if desired. Remote control operates
from minimum to maximum of preset am-
perage value. Connect remote control de-
vice according to Section 4-13.
When parameter change or selection is lim-
ited by lock level 4, [LOCK][LEV4] is dis-
played as a reminder.
L2
L2
L2
L1
L3
Use Encoder Control To Adjust
Amperage
10% Of Preset
Value.
L3
Levels 1, 2, And 3
Level 4
A
J
B
K
I
C L N
H
D M
G
E
F
Indicates which functions are available
for the corresponding lockout level.
Содержание DYNASTY 350
Страница 6: ......
Страница 16: ...OM 216 869 Page 10...
Страница 26: ...OM 216 869 Page 20 Notes...
Страница 84: ...OM 216 869 Page 78 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram For Dynasty 350 Models...
Страница 85: ...OM 216 869 Page 79 243 217 C...
Страница 86: ...OM 216 869 Page 80 Figure 8 2 Circuit Diagram For Maxstar 350 Models...
Страница 87: ...OM 216 869 Page 81 243 215 C...
Страница 88: ...OM 216 869 Page 82 Figure 8 3 Circuit Diagram For Dynasty 700 Models Part 1 of 2...
Страница 89: ...OM 216 869 Page 83 243 218 C...
Страница 90: ...OM 216 869 Page 84 Figure 8 4 Circuit Diagram For Dynasty 700 Models Part 2 of 2...
Страница 91: ...OM 216 869 Page 85 243 218 C...
Страница 92: ...OM 216 869 Page 86 Figure 8 5 Circuit Diagram For Maxstar 700 Models Part 1 of 2...
Страница 93: ...OM 216 869 Page 87 243 216 C...
Страница 94: ...OM 216 869 Page 88 Figure 8 6 Circuit Diagram For Maxstar 700 Models Part 2 of 2...
Страница 95: ...OM 216 869 Page 89 243 216 C...
Страница 96: ...OM 216 869 Page 90 228 525 B Figure 8 7 Circuit Diagram For Cooler...
Страница 121: ...OM 216 869 Page 115 Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...