OM-216 869 Page 36
4-14. Automation Connection (For 28-Pin Receptacle If Present)
803 900-A / 218 716-A
1
4
9
15
21
26
28
25
20
14
8
3
2
7
6
5
13 12 11
10
19 18 17
16
24 23 22
27
Pin
Pin Information For 28-Pin Receptacle RC28
1
Start/Stop - Closure to pin 8 starts the weld cycle. Opening closure stops weld cycle. During 2T operation, a momentary closure
(greater than 100 ms, but less than 3/4 seconds) starts and stops weld output.
2
Output enable - functional only in automation modes - Closure to pin 8 must be maintained at all times. If the closure between pins 2
and 8 is broken, an output disable occurs, Postflow begins to time out, and
AUTO STOP will be displayed on the meters.
3
Gas - Closure to pin 8 turns on gas. This input will override Postflow, but if a Preflow time is entered, the Preflow cycle will time out
before arc initiation.
4
Valid arc, collector - Output is on when the contactor is on and there is less than 50 load volts (see Section 4-17).
5
Voltage feedback - +1 volt DC per 10 volts w/reference to pin 11.
6
Current feedback - +1 volt DC per 100 amperes w/reference to pin 11.
7
Not used
8
IGND isolation common
9
Valid arc, emitter - Output is on when the contactor is on and there is less than 50 load volts (see Section 4-17).
10
Memory Select 2 - See Section 4-15.
11
Remote control circuit common for pins 17 and 18
12
Chassis common
13
Pulse lockout, collector - Output is on when in Initial Amperage, Initial Slope, Final Slope, Final Amperage, and Pulsed Background
time when the pulse frequency is less than 10 Hz (see Section 4-17).
14
Pulse lockout, emitter - Output is on when in Initial Amperage, Initial Slope, Final Slope, Final Amperage, and Pulse Background
time, when the pulse frequency is less than 10 Hz (see Section 4-17).
15
Memory select 0 - See Section 4-15.
16
Memory select 1 - See Section 4-15.
17
Command signal from remote control - 0 to +10 volts DC input (do not use if pulse output is controlled by an external source).
18
+10 volts DC for use with an external potentiometer
19
HF disable - Disables high frequency when connected to pin 8.
20
Automation enable 1 - See Section 4-16.
21
Amperage EN common - See Section 4-16.
22
Amperage EN command - See Section 4-16.
23
Final slope, collector - Output is on when in Final Slope (see Section 4-17).
24
Final slope, emitter - Output is on when in Final Slope (see Section 4-17).
25
Automation enable 2 - See Section 4-16.
26
Amperage EP command (Dynasty models only) - See Section 4-16.
27
Amperage EP common (Dynasty models only) - See Section 4-16.
28
Polarity (Dynasty models only) - See Section 4-16.
Содержание DYNASTY 350
Страница 6: ......
Страница 16: ...OM 216 869 Page 10...
Страница 26: ...OM 216 869 Page 20 Notes...
Страница 84: ...OM 216 869 Page 78 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram For Dynasty 350 Models...
Страница 85: ...OM 216 869 Page 79 243 217 C...
Страница 86: ...OM 216 869 Page 80 Figure 8 2 Circuit Diagram For Maxstar 350 Models...
Страница 87: ...OM 216 869 Page 81 243 215 C...
Страница 88: ...OM 216 869 Page 82 Figure 8 3 Circuit Diagram For Dynasty 700 Models Part 1 of 2...
Страница 89: ...OM 216 869 Page 83 243 218 C...
Страница 90: ...OM 216 869 Page 84 Figure 8 4 Circuit Diagram For Dynasty 700 Models Part 2 of 2...
Страница 91: ...OM 216 869 Page 85 243 218 C...
Страница 92: ...OM 216 869 Page 86 Figure 8 5 Circuit Diagram For Maxstar 700 Models Part 1 of 2...
Страница 93: ...OM 216 869 Page 87 243 216 C...
Страница 94: ...OM 216 869 Page 88 Figure 8 6 Circuit Diagram For Maxstar 700 Models Part 2 of 2...
Страница 95: ...OM 216 869 Page 89 243 216 C...
Страница 96: ...OM 216 869 Page 90 228 525 B Figure 8 7 Circuit Diagram For Cooler...
Страница 121: ...OM 216 869 Page 115 Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...