OM-216 869 Page 27
C. Dynasty 700 Models
Actual input voltage should not be 10% less than minimum (5% for 380 volt CE models) and/or 10% more than maximum input voltages listed
in table. If actual input voltage is outside this range, output may not be be available.
NOTICE
−
INCORRECT INPUT POWER can damage this welding power source. Phase to ground voltage shall not 10% of rated input volt-
age.
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.
Three-Phase
Input Voltage (V)
208
230
380
400
460
575
Input Amperes (A) At Rated Output - 600 amps @ 44 volts
98
88
53
51
44
33
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay Fuses
2
110
100
60
60
50
40
Normal Operating Fuses
3
150
125
80
80
70
50
Min Input Conductor Size In AWG
4
4
4
8
8
8
10
Max Recommended Input Conductor Length In Feet (Meters)
118
(36)
144
(44)
160
(49)
177
(54)
235
(72)
240
(73)
Min Grounding Conductor Size In AWG
4
6
6
8
8
8
10
Reference: 2008 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5” . See UL 248.
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommenda-
tions are for a dedicated branch circuit sized for the rated output and duty cycle of the welding power source.
Single-Phase
Input Voltage (V)
208
230
460
575
Input Amperes (A) At Rated Output - 450 amps @ 38 volts
119
105
50
38
Max Recommended Standard Fuse Rating In Amperes
1
Time-Delay Fuses
2
125
125
60
50
Normal Operating Fuses
3
175
150
80
60
Min Input Conductor Size In AWG
4
3
4
8
8
Max Recommended Input Conductor Length In Feet (Meters)
107
(33)
107
(33)
178
(54)
279
(85)
Min Grounding Conductor Size In AWG
4
6
6
8
10
Reference: 2008 National Electrical Code (NEC) (including article 630)
1 If a circuit breaker is used in place of a fuse, choose a circuit breaker with time-current curves comparable to the recommended fuse.
2 “Time-Delay” fuses are UL class “RK5” . See UL 248.
3 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amps), and UL class “H” ( 65 amps and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
Содержание DYNASTY 350
Страница 6: ......
Страница 16: ...OM 216 869 Page 10...
Страница 26: ...OM 216 869 Page 20 Notes...
Страница 84: ...OM 216 869 Page 78 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram For Dynasty 350 Models...
Страница 85: ...OM 216 869 Page 79 243 217 C...
Страница 86: ...OM 216 869 Page 80 Figure 8 2 Circuit Diagram For Maxstar 350 Models...
Страница 87: ...OM 216 869 Page 81 243 215 C...
Страница 88: ...OM 216 869 Page 82 Figure 8 3 Circuit Diagram For Dynasty 700 Models Part 1 of 2...
Страница 89: ...OM 216 869 Page 83 243 218 C...
Страница 90: ...OM 216 869 Page 84 Figure 8 4 Circuit Diagram For Dynasty 700 Models Part 2 of 2...
Страница 91: ...OM 216 869 Page 85 243 218 C...
Страница 92: ...OM 216 869 Page 86 Figure 8 5 Circuit Diagram For Maxstar 700 Models Part 1 of 2...
Страница 93: ...OM 216 869 Page 87 243 216 C...
Страница 94: ...OM 216 869 Page 88 Figure 8 6 Circuit Diagram For Maxstar 700 Models Part 2 of 2...
Страница 95: ...OM 216 869 Page 89 243 216 C...
Страница 96: ...OM 216 869 Page 90 228 525 B Figure 8 7 Circuit Diagram For Cooler...
Страница 121: ...OM 216 869 Page 115 Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...