![Miller DIMENSION NT 450 WCC Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/miller/dimension-nt-450-wcc/dimension-nt-450-wcc_owners-manual_1796112028.webp)
OM-240 044 Page 24
SECTION 5 − OPERATION
5-1.
Controls
239 918-D
1
2
3
6
7
4
5
1
Power Switch
This unit is equipped with a fan motor that
is thermostatically controlled and only
runs when cooling is needed.
2
3
4
Mode Switch
Use Mode switch to determine both process
and output On/Off control. Orange areas
highlight “contactor on” positions.
5
Panel/Remote Control Switch
For front panel control, place switch in Panel
position and use the V/A Adjust control to set
amperage or voltage, depending on Mode
switch selection.
For remote control, make connections to Re-
mote 14 receptacle (see Section 4-12), and
place switch in Remote position. In TIG
modes, output available through the remote
control is a percent of the V/A Adjust control
setting. Value selected on V/A Adjust control
is maximum output available through the re-
mote control. In the MIG, CC, and V-Sense
feeder (with WCC inactive) modes, a remote
control provides full range of unit output re-
gardless of V/A Adjust control setting. A re-
mote control is not functional in Air-Carbon
Arc or Stick modes. If connection to Remote
14 receptacle is removed and Panel/Remote
control switch remains in Remote position,
output is controlled with the V/A Adjust con-
trol. For operation with a V-Sense feeder with
WCC, Panel/Remote switch should be set to
Panel position.
6
V/A (Voltage/Amperage) Adjust Control
With Mode switch in any Stick or TIG position,
use control to adjust amperage from 5 to 500
amps. With Mode switch in a V-Sense Feeder
(with WCC inactive) or MIG position, use
control to adjust voltage from 10 to 38 volts.
In V-Sense feeder mode with WCC active,
control is overridden.
7
Inductance/Dig Control
Control adjusts Dig when a Stick or CC mode
is selected on mode switch. When set to-
wards minimum, short-circuit amperage at
low arc voltage is the same as normal welding
amperage. When set to max, control in-
creases short-circuit amperage at low arc
voltage. This allows the operator to use a
very short arc length without sticking the
electrode. As control is adjusted, the amount
of Dig selected is displayed on the amps me-
ter as a percentage (0 to 100%) of full range,
and
dig
is displayed on the volts meter.
When Air-Carbon Arc mode is selected, Dig
is internally set to max.
Control adjusts inductance when MIG or V-
Sense Feeder position is selected on mode
switch. Inductance determines the “wetness”
of the weld puddle. As setting is increased to-
wards maximum, “wetness” (puddle fluidity)
increases. As control is adjusted, the amount
of inductance selected is displayed on the
amps meter as a percentage (0 to 100%) of
full range, and
ind
is displayed on the volts
meter.
This control is not functional when one of the
TIG modes is selected.
Change control setting to best suite
application.