OM-4403 Page 25
6-2.
Optional Generator Power Receptacles
If unit does not have GFCI recep-
tacles, use GFCI-protected exten-
sion cord.
Generator power decreases as weld
current increases.
Set Fine Control R1 at 10 for full genera-
tor power.
Combined output of all receptacles limited to
10 kVA/kW rating of the generator.
CSA Receptacle Option
Receptacles supply 60 Hz single-phase
power at weld/power speed. Receptacles
and generator power output are the same as
on standard unit (see Section 6-1).
1
Circuit Breaker CB1
CB1 protects RC1 from overload. If CB1
opens, the receptacles do not work. Push
switch up to reset breaker. Circuit breaker
protection for remaining receptacles is the
same as on standard unit (see Section 6-1).
GFCI Receptacle Option
2
120 V 20 A AC GFCI Receptacles
GFCI-2 and GFCI-3
GFCI2 and GFCI3 supply 60 Hz single-
phase power at weld/power speed. Maxi-
mum output from GFCI-2 or GFCI-3 is 2.4
kVA/kW. Circuit breaker protection is the
same as standard receptacles.
If a ground fault is detected, the GFCI Reset
button pops out and the circuit opens to dis-
connect the faulty equipment. Check for
damaged tools, cords, plugs, etc. con-
nected to the receptacle. Press button to re-
set receptacle and resume operation.
Power is still present at the 240 volt
receptacle when only one circuit
breaker trips.
Unplug power cord before attempt-
ing to service accessories or tools.
At least once a month, run engine at
weld/power speed and press Test but-
ton to verify GFCI is working properly.
South African And Australian Recepta-
cle Options
3
240 V 16 A AC South African Recep-
tacles RC1, RC2, and RC3
4
240 V 15 A AC Australian Recep-
tacles RC1, RC2, and RC3
Receptacles supply 60 Hz single-phase
power at weld/power speed. Maximum out-
put from each receptacle is 3.6 kVA/kW.
5
Circuit Breakers CB1, CB2, CB3
CB1, CB2, and CB3 protect RC1, RC2, and
RC3 from overload. If a circuit breaker
opens, the receptacle does not work.
6
Circuit Breaker CB4
CB4 protects all the receptacles from over-
load. If CB4 opens, none of the receptacles
work.
Press button to reset circuit breaker. If
breaker continues to open, contact Fac-
tory Authorized Service Agent.
2
3
5
6
4
5
6
Ref. 205 903 / 200 017 / Ref. 172 782-B / Ref. 172 113-A