11.3 Grounding When Supplying Building Systems
ST-800 576-B
1
Equipment Grounding
Terminal
2
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
3
Ground Device
Ground generator to system
earth ground if supplying
power to a premises (home,
shop, farm) wiring system.
GND/PE
1
2
Use ground device as stated
in electrical codes.
2
3
11.4 How Much Power Does Equipment Require?
S-0623
1
Resistive Load
A light bulb is a resistive load and
requires a constant amount of pow-
er.
2
Non-Resistive Load
Equipment with a motor is a non-re-
sistive load and requires approxi-
mately six times more power while
starting the motor than when run-
ning (see Section 11.8).
3
Rating Data
Rating shows volts and amperes,
or watts required to run equipment.
VOLTS 115
4.5
60
AMPS
Hz
1
2
3
3
EXAMPLE 1: If a drill uses 4.5 amperes at 115 volts, calculate its running power
requirement in watts.
4.5 A x 115 V = 520 W
The load applied by the drill is 520 watts.
EXAMPLE 2: If three 200 watt flood lamps are used with the drill from Example 1,
add the individual loads to calculate total load.
The total load applied by the three flood lamps and drill is 1120 watts.
(200 W + 200 W + 200 W) + 520 W = 1120 W
AMPERES x VOLTS = WATTS
Содержание Bobcat 225 NT
Страница 4: ......
Страница 39: ...35 OM 405 10 Electrical Diagrams 10 1 Circuit Diagram For Welding Generator Onan Powered Units SB 180 688...
Страница 40: ...36 OM 405 10 2 Circuit Diagram For Welding Generator Kohler Powered Units SB 183 459 A...
Страница 65: ...61 OM 405 Notes...
Страница 70: ...Notes...
Страница 71: ...Notes...
Страница 72: ...Notes...